文献速递胃肠外科

吲哚菁绿荧光成像预防结直肠吻合口漏的随机临床试验

Indocyanine Green Fluorescence Imaging in Prevention of Colorectal Anastomotic Leakage: A Randomized Clinical Trial.
PubMed 文献 · JAMA Surg · 2025-01-01

ICG-COLORAL 研究在 5 家芬兰公立医院纳入 1136 例择期腹腔镜结直肠切除(排除低位前切除)患者,随机分为 ICG 荧光成像组与对照组。右侧手术 OR 0.87(95%CI 0.46-1.65),左侧手术 OR 0.55(95%CI 0.29-1.05);无 ICG 相关不良事件。

要点

  • 左侧手术 ICG 组漏率 5.2% vs 9.5%,OR 0.55(95%CI 0.29-1.05)。
  • 研究排除低位前切除,结论不适用于该人群。

核心结论

  • 在排除低位前切除的腹腔镜结直肠手术中,常规使用 ICG 荧光成像未显著降低总体吻合口漏率,但左侧手术可能获益。

研究设计与样本

  • 纳入择期腹腔镜结直肠切除、排除低位前切除、计划一期吻合的患者,意向性治疗人群 1136 例,女性 526 例(46.3%),男性 610 例(53.7%),平均(SD)年龄 70(11)岁,BMI 28(5),年龄校正 Charlson 合并症指数 5(3)。
  • 干预组吻合前后各静脉给予 5 mg ICG 并以近红外相机评估荧光信号,对照组不接受 ICG 荧光成像。

主要发现

  • 右侧手术吻合口漏率 ICG 组 5.9%(16/273)对对照组 6.7%(20/298),OR 0.87(95%CI 0.46-1.65)。
  • 左侧手术吻合口漏率 ICG 组 5.2%(14/267)对对照组 9.5%(23/243),OR 0.55(95%CI 0.29-1.05)。
  • 无患者报告与 ICG 相关的不良事件。

临床怎么用

  • 在排除低位前切除的腹腔镜结直肠手术中,不应期待 ICG 荧光成像普遍降低吻合口漏率。
  • 对左侧结直肠手术可考虑使用 ICG 荧光成像评估吻合口灌注,但需结合个体风险判断。

局限性

  • 研究排除低位前切除,结论不能外推至该人群。
  • 总体及左侧手术比较的置信区间均包含无效值,左侧手术的潜在获益需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

IMPORTANCE: Performing a bowel anastomosis is a critical step in colorectal resection. Assessing the risk of anastomotic leakage remains challenging, even for experienced surgeons. OBJECTIVE: To evaluate the use of indocyanine green (ICG) fluorescence imaging in assessing perfusion at the anastomotic site before and after anastomosis and determine whether it helps reduce anastomotic leakages. DESIGN, SETTING, AND PARTICIPANTS: ICG-COLORAL is a prospective, randomized, multicenter study conducted from September 1, 2018, to December 31, 2023. Participants were recruited during preoperative outpatient clinic visits by clinicians not involved in the study, as well as by researchers. Participants were elective patients scheduled for laparoscopic resections, excluding low anterior resections, with planned primary anastomosis in 5 Finnish public hospitals experienced in laparoscopic colorectal surgery. INTERVENTION: The intervention group received 5 mg of ICG intravenously before and after anastomosis formation. The fluorescence signal was assessed with a near-infrared-capable camera. The control group did not receive ICG fluorescence imaging. MAIN OUTCOME AND MEASURE: The primary outcome measure was the anastomotic leak rate as detected by computed tomography. RESULTS: Among 1136 patients in the intention-to-treat population, 526 (46.3%) were female and 610 (53.7%) male; they had a mean (SD) age of 70 (11) years, body mass index of 28 (5), and age-adjusted Charlson Comorbidity Index of 5 (3). Overall, the anastomotic leak rate was 5.8% (33/567) in the ICG fluorescence imaging group vs 7.9% (45/569) in the control group (odds ratio [OR], 0.73; 95% CI, 0.48-1.13; P = .16). For right-sided operations, the anastomotic leak rate with ICG fluorescence imaging was 5.9% (16/273) vs 6.7% (20/298) in the control group (OR, 0.87; 95% CI, 0.46-1.65). For left-sided operations, the anastomotic leak rate was 5.2% (14/267) with ICG fluorescence imaging vs 9.5% (23/243) without (OR, 0.55; 95% CI, 0.29-1.05). No patients reported adverse events related to ICG. CONCLUSIONS AND RELEVANCE: This study found that routine use of ICG fluorescence imaging does not significantly reduce the overall anastomotic leak rate in laparoscopic colorectal surgery if low anterior resections are excluded but may be beneficial in left-sided operations. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03602677.

来源:JAMA Surg,查看原文。版权归原作者所有。

引用

  1. Rinne JKA, Huhta H, Pinta T, et al. Indocyanine Green Fluorescence Imaging in Prevention of Colorectal Anastomotic Leakage: A Randomized Clinical Trial. JAMA Surg. 2025. PMID: 40042831. doi:10.1001/jamasurg.2025.0006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。