术中评估吻合口血管化的新技术预防低位前直肠切除吻合口漏的初步研究
本研究报道使用入射暗场视频显微镜(IDF)测量肠微循环密度和血流,以评估低位前直肠切除吻合口血管化的初步经验,并通过倾向性评分匹配比较手术结局。无Cytocam组2例发生吻合口漏(p=0.811)。结论认为该评估方法可行、安全且有助于在吻合前发现切除结肠的血管化异常。
要点
- IDF视频显微镜可术中评估结肠微循环,操作可行且安全。
- 2例(10.5%)因血管化异常改变手术策略并扩大切除。
- 吻合口漏发生率与无Cytocam组比较无显著差异(p=0.811)。
核心结论
- 该吻合口评估技术可行、安全,能简便检测吻合前切除结肠的血管化异常。
- 该技术可能比其他设备更具成本效益。
研究设计与样本
- 在结肠切除后从左半结肠断端黏膜和浆膜面各记录5个位点视频(每位点至少10秒)。
- 采用倾向性评分匹配(基于年龄、性别和Charlson合并症指数)分析微循环评估与术后结局的关联。
主要发现
- Cytocam组平均TVD small为8.9 ± 2.8 mm/mm2。
- 除1例外所有患者PPV small %为100,所有患者MFI为3。
- 平均PVD small为8.76 ± 2.8 mm/mm2,平均De Backer评分为4.4 ± 1.3。
- 2例(10.5%)因血管化异常改变手术策略并扩大切除点。
- 无Cytocam组2例发生吻合口漏(p = 0.811)。
临床怎么用
- 可在低位前直肠切除中吻合前使用IDF视频显微镜评估结肠断端微循环。
- 发现血管化异常时可考虑扩大切除范围以降低吻合口漏风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Altered vascular microcirculation is recognized as a risk factor for anastomotic leakage (AL) in colorectal surgery. However, few studies evaluated its impact on AL using different devices, with heterogeneous results. The present study reported the initial experience measuring gut microcirculatory density and flow with the aid of incidence dark-field (IDF) videomicroscopy (Cytocam, Braedius, Amsterdam, The Netherlands) comparing its operative outcome using a propensity score matching (PSM) model based on age, gender, and Charlson Comorbidity Index (CCI). MATERIALS AND METHODS: Videos from 5 different sites (at least 10 s/site) were recorded from both the mucosal and serosal site of the left colon end after the colonic resection. Total vessel density (TVD), Perfused Vessel Density (PVD), De Backer score, Proportion of Perfused Vessels (PPV), and Microvascular Flow Index (MFI) were analyzed. At each recording, noninvasive measurements of blood pressure, heart rate, temperature, use of vasoactive drugs, and peripheral oxygen saturation were simultaneously recorded. The association between postoperative outcomes and microcirculation evaluation was investigated using PSM analyses. RESULTS: Ninety-nine patients were included in the Cytocam group. The mean TVD small was 8.9 ± 2.8 mm/mm2, the PPV small % was 100 in all patients but 1, while the MFI was 3 in all patients. The mean PVD small was 8.76 ± 2.8 mm/mm2 and the mean De Becker score was 4.4 ± 1.3. In 2 patients (10.5%), the finding of altered vascularization resulted in the change of the operative strategy with an extension of the resection point. AL occurred in 2 patients of the No Cytocam group (p = 0.811). CONCLUSION: This type of anastomotic evaluation has shown to be feasible, safe, and useful in easily detecting any alteration of the resected colon before anastomotic construction. Moreover, this technology could offer a more cost-effective manner than other devices.
引用
- Ortenzi M, Carsetti A, Picchetto A, et al. Implementation of intraoperative procedures to prevent anastomotic leak in low anterior rectal resections: a pilot study for a novel technique to evaluate anastomotic vascularization. Surg Endosc. 2025. PMID: 39870829. doi:10.1007/s00464-024-11506-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。