文献速递胃肠外科围术期管理与 ERAS

回盲部体内吻合模拟训练模块的设计与验证

Design and validation of a simulation-based training module for ileo-transverse intracorporeal anastomosis.
PubMed 文献 · Surg Endosc · 2025-01-13

本研究开发并验证了一种用于回盲部体内吻合(ICA)的离体模拟训练模块。通过迭代过程构建模型后,13名不同经验术者进行操作,由两名盲法评估者使用改良OSATS和特定评分量表评估。专家OSATS评分更高(22.3 vs 18,p=.013),手术时间更短(21.5 vs 36分钟,p=.039),证实了结构效度。

要点

  • 专家OSATS评分显著高于新手(22.3 vs 18,p=.013)。
  • 专家手术时间显著短于新手(21.5 vs 36分钟,p=.039)。

核心结论

  • 离体模拟模块在复制手术环境方面表现出可接受的保真度。
  • 模拟场景能通过OSATS评分和手术时间的显著差异区分手术经验水平,证实结构效度。

研究设计与样本

  • 概念验证设计的教育工具研究。
  • 通过团队手术经验、手术视频和现有证据确定吻合关键环节,迭代优化模拟模型至功能原型。
  • 招募不同经验水平外科医生在模型上执行ICA,两名盲法评估者通过视频使用改良OSATS、特定评分量表(SRS)和手术时间评估表现。
  • 采用非参数描述和分析方法,结果以中位数[IQR]表示。

主要发现

  • 所有参与者认为模型对训练体内缝合有用。
  • 13名受试者执行ICA,专家OSATS评分显著更高(22.3 [22-22.5] vs 18 [16-19.5];p=.013)。
  • 专家SRS有更高趋势,手术时间更短(21.5 vs 36分钟;p=.039)。

临床怎么用

  • 该离体模拟模块可用于回盲部体内吻合的训练,并能区分不同经验水平。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The benefits of the totally laparoscopic right hemicolectomy have been established, but its adoption has been limited by the challenges of intracorporeal suturing. While simulation is effective for training advanced surgical skills, no dedicated simulation-based course exists for intracorporeal ileo-transverse anastomosis (ICA). This study aimed to develop and validate a simulation module for training in ICA. METHODS: This study employed a proof-of-concept design for an educational tool. Key aspects of the anastomosis were identified using the team's surgical experience, surgical videos, and existing evidence. Surgeons were recruited to test and refine successive simulation models through an iterative process until a functional prototype was achieved and assessed. Subsequently, surgeons with varying experience levels were invited to perform an ICA in the model. Performance was evaluated by two blinded surgeons through video recordings, utilizing a modified Objective Structured Assessment of Technical Skills (OSATS), a Specific Rating Score (SRS), and operative time measurements. Non-parametric descriptive and analytical methods were applied, with results presented as median [IQR]. RESULTS: An ex vivo based model was developed. Seventeen participants evaluated the model. Eighty-three percent declared acceptable or maximum fidelity regarding the colon. Resemblance to the surgical scenario in terms of ergonomic and anatomical similarity was highlighted. All participants found the model useful to train intracorporeal suturing. Thirteen subjects performed the ICA. Experts achieved significantly higher OSATS scores (22.3 [22-22.5] vs 18 [16-19.5]; p = .013), exhibited a trend toward higher SRS, and obtained shorter operative times (21.5 vs 36 min; p = .039). CONCLUSION: An ex vivo simulation module for ICA was developed, demonstrating acceptable fidelity in replicating the surgical environment. The simulated scenario could successfully distinguish between levels of surgical experience, as evidenced by significant differences in OSATS scores and operative times, thereby confirming its construct validity.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Jarry C, Varas J, Inzunza M, et al. Design and validation of a simulation-based training module for ileo-transverse intracorporeal anastomosis. Surg Endosc. 2025. PMID: 39806177. doi:10.1007/s00464-024-11516-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。