猪小肠黏膜下层补片与聚丙烯补片在腹腔镜经腹腹膜前腹股沟疝修补术中的结局比较:回顾性队列研究

Outcomes of porcine small intestinal submucosa mesh compared to polypropylene mesh in laparoscopic transabdominal preperitoneal inguinal hernia repair: a retrospective cohort study.
PubMed 文献 · Surg Endosc · 2024-12-09

该回顾性队列研究比较了猪小肠黏膜下层(SIS)补片与聚丙烯(PP)补片在腹腔镜经腹腹膜前(TAPP)腹股沟疝修补术后的长期结局。经过倾向性评分匹配后,SIS组手术时间更长,术后不适报告率更高(8.8% vs. 0.9%,P=0.006),复发率虽在SIS组更高(4.4% vs. 0%),但无统计学差异(P=0.06)。结论提示SIS补片在TAPP中可能导致更频繁的不适和更高的复发率,但需进一步随访和扩大样本验证。

要点

  • SIS补片在TAPP腹股沟疝修补中手术时间显著长于PP补片。
  • SIS组术后不适报告率显著高于PP组,尤其在运动时更明显。
  • SIS组复发率数值更高但无统计学差异,需更大样本验证。

核心结论

  • 在TAPP腹股沟疝修补术中,SIS补片相比PP补片导致更频繁的术后不适和更高的复发率(但无统计学差异)。
  • 需要继续随访和增加样本量以分析SIS补片的有效性及复发危险因素。

研究设计与样本

  • 回顾性队列研究,纳入北京朝阳医院2014年1月1日至2018年12月31日期间连续进行的腹腔镜腹股沟疝修补术患者。
  • 共筛选2348例患者,最终纳入1240例单侧疝TAPP手术进行统计分析,其中143例(11.5%)使用SIS补片。
  • 采用倾向性评分匹配(基于年龄、性别、BMI)后形成115对匹配病例进行比较分析,随访至2024年1月30日。

主要发现

  • SIS补片组平均手术时间63.2 ± 18.5 min,长于PP补片组的50.1 ± 17.6 min(P < 0.001)。
  • SIS补片更常用于斜疝修补,而PP补片更常用于直疝和股疝(P = 0.009)。
  • 平均随访84.2个月,失访7例(3%);术后总复发5例(2.3%),均在SIS组,但两组比较无统计学差异(4.4% vs. 0%;P = 0.06)。
  • SIS组术后不适报告率高于PP组(8.8% vs. 0.9%;P = 0.006),尤其在运动时更频繁和严重。
  • 复发病例均接受再次手术(3例TAPP,2例Lichtenstein),术后无再复发。

临床怎么用

  • 对于接受TAPP腹股沟疝修补的患者,选择SIS补片需权衡术后不适和复发风险,尤其对于年轻男性患者。
  • SIS补片手术时间较长,可能影响手术效率。
  • 术后应关注患者运动时的不适主诉,并加强随访以监测复发。

局限性

  • 回顾性研究设计,可能存在选择偏倚。
  • SIS组样本量较小(匹配后115对),复发事件数少,统计效能有限。
  • 随访期间失访率3%,可能影响结果稳定性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To compare the long-term outcomes of porcine small intestinal submucosa (SIS) mesh and polypropylene (PP) mesh after an laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair. BACKGROUND: Mesh-based surgical techniques for inguinal hernia repair are recommended in the guidelines due to the lower rate of recurrence. Biologic meshes (BMs) may have advantages in terms of chronic pain due to the different postoperative remodeling, without the disadvantages of a permanent implant. SIS mesh is the most commonly used BMs, mostly used for young male patients. Until now, the long-term efficacy of SIS mesh in laparoscopic inguinal hernia repair (LIHR) has rarely been reported and remains elusive. METHODS: We retrospectively reviewed prospectively collected data from consecutive LIHR performed at Beijing Chaoyang Hospital between January 1, 2014 and December 31, 2018. Two groups of meshes were selected: SIS mesh and PP mesh. To reduce potential selection bias, patients were matched based on the logit of propensity scores through age, gender, and body mass index (BMI). Follow-up was until January 30, 2024. Long-term outcomes were analyzed, including the rate of recurrence, the rate of re-operation, and the postoperative discomfort. RESULTS: A total of 2,348 patients with LIHR were eligible. After exclusion criteria, a total of 1,240 unilateral hernias treated using the TAPP approach were included for statistical analysis. Of these, 143 hernias (11.5%) were operated on with SIS mesh. Applying propensity score matching resulted in 115 matched pairs for comparative analysis. The mean operative time with the SIS mesh was 63.2 ± 18.5 min, which was longer than the operative time with PP mesh of 50.1 ± 17.6 min (P < 0.001). The SIS mesh was used more frequently to repair indirect hernias, while the PP mesh was more often employed to direct and femoral hernias at a higher rate (P = 0.009). The mean follow-up was 84.2 months and a total of seven patients (3%) were lost to follow-up. Overall, five (2.3%) patients experienced hernia recurrence postoperatively, all in the SIS group, but no statistical difference was observed between the two groups (4.4% vs. 0%; P = 0.06). All underwent a second operation, with three in TAPP approach and two in Lichtenstein approach, no recurrence was found afterward. More patients in the SIS group reported postoperative discomfort than those in the PP group (8.8% vs. 0.9%; P = 0.006), notably experiencing discomfort more frequently and to a greater degree during movement. CONCLUSION: The SIS mesh in TAPP hernia repair leads to more frequent discomfort and a higher recurrence rate (though not statistically significant) compared to PP mesh. Continued follow-up and an increased sample size are needed to analyze the effectiveness of SIS mesh and to explore risk factors for recurrence.

来源:Surg Endosc,查看原文。版权归原作者所有。