人工智能术中检测甲状旁腺:数据增强优化医学图像训练
本研究收集150例单侧甲状腺叶切除术中经细针穿刺确认的152张甲状旁腺图像,训练三种数据增强方案的人工智能模型用于术中检测甲状旁腺。基线模型平均精度为77%,几何变换增强为79%,图像修复增强为78.6%;外部验证中图像修复增强达46%,优于几何变换的37%和基线的33%。
要点
- 基线AI模型术中检测甲状旁腺平均精度为77%。
- 几何变换增强平均精度79%,图像修复增强为78.6%。
- 外部验证中图像修复增强效果最好,平均精度为46%。
核心结论
- 该AI模型可有效且可泛化地用于甲状腺切除术中甲状旁腺的术中识别,尤其在适当数据增强方法辅助下。
- 尚需额外研究比较模型性能与外科医生识别能力,以评估该AI模型的真实临床相关性。
研究设计与样本
- 从甲状腺叶切除术手术视频中采集甲状旁腺图像,经细针穿刺确认的图像用于训练。
- 根据增强状态构建三类数据集:基线、几何变换、基于生成对抗网络的图像修复。
- 主要结局为AI检测甲状旁腺的平均精度。
- 共从150例接受单侧甲状腺叶切除术的患者中获取152张经细针穿刺确认的甲状旁腺图像。
主要发现
- 基于基线数据的AI模型检测甲状旁腺的平均精度为77%。
- 应用几何变换和图像修复增强后性能提升,几何变换数据集平均精度为79%,高于图像修复模型的78.6%。
- 使用完全不同的甲状腺切除术式进行外部验证时,图像修复方法更有效(46%),优于几何变换(37%)和基线(33%)。
临床怎么用
- 在甲状腺切除术中可考虑使用经适当数据增强训练的AI模型辅助术中识别甲状旁腺。
- 图像修复增强在跨术式外部验证中表现更优,可能更适合泛化场景。
局限性
- 尚需额外研究比较模型性能与外科医生识别能力,以评估真实临床相关性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Postoperative hypoparathyroidism is a major complication of thyroidectomy, occurring when the parathyroid glands are inadvertently damaged during surgery. Although intraoperative images are rarely used to train artificial intelligence (AI) because of its complex nature, AI may be trained to intraoperatively detect parathyroid glands using various augmentation methods. The purpose of this study was to train an effective AI model to detect parathyroid glands during thyroidectomy. METHODS: Video clips of the parathyroid gland were collected during thyroid lobectomy procedures. Confirmed parathyroid images were used to train three types of datasets according to augmentation status: baseline, geometric transformation, and generative adversarial network-based image inpainting. The primary outcome was the average precision of the performance of AI in detecting parathyroid glands. RESULTS: 152 Fine-needle aspiration-confirmed parathyroid gland images were acquired from 150 patients who underwent unilateral lobectomy. The average precision of the AI model in detecting parathyroid glands based on baseline data was 77%. This performance was enhanced by applying both geometric transformation and image inpainting augmentation methods, with the geometric transformation data augmentation dataset showing a higher average precision (79%) than the image inpainting model (78.6%). When this model was subjected to external validation using a completely different thyroidectomy approach, the image inpainting method was more effective (46%) than both the geometric transformation (37%) and baseline (33%) methods. CONCLUSION: This AI model was found to be an effective and generalizable tool in the intraoperative identification of parathyroid glands during thyroidectomy, especially when aided by appropriate augmentation methods. Additional studies comparing model performance and surgeon identification, however, are needed to assess the true clinical relevance of this AI model.
引用
- Lee JH, Ku E, Chung YS, et al. Intraoperative detection of parathyroid glands using artificial intelligence: optimizing medical image training with data augmentation methods. Surg Endosc. 2024. PMID: 39138679. doi:10.1007/s00464-024-11115-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。