文献速递甲状腺与颈部外科围术期管理与 ERAS

人工智能利用近红外自体荧光信号在离体标本中识别甲状旁腺组织

The use of artificial intelligence to detect parathyroid tissue on ex vivo specimens during thyroidectomy and parathyroidectomy procedures using near-infrared autofluorescence signals.
PubMed 文献 · Surgery · 2024-08-14

本研究基于甲状腺切除术和甲状旁腺切除术中离体标本的近红外自体荧光图像,开发深度学习模型以区分甲状旁腺组织。模型在测试集上检测甲状旁腺组织的精确率、召回率和曲线下面积分别为96.5%、96.5%和0.985。假阴性主要与颜色暗且体积大的甲状旁腺相关。

要点

  • 深度学习模型基于近红外自体荧光图像识别离体标本中的甲状旁腺组织。
  • 模型检测甲状旁腺的精确率、召回率和AUC分别为96.5%、96.5%和0.985。
  • 假阴性主要与颜色暗且体积大的甲状旁腺相关。

核心结论

  • 基于近红外自体荧光的视觉深度学习模型在离体标本中识别甲状旁腺组织表现出高敏感性和阳性预测值。
  • 该模型有望减少术中冰冻切片和甲状旁腺激素抽吸确认甲状旁腺组织的需求,从而提高手术效率。

研究设计与样本

  • 单中心学术中心于2019年11月至2023年4月期间建立甲状腺切除术和甲状旁腺切除术离体标本的近红外自体荧光图像库。
  • 共使用来自678例手术的1151张图像训练深度学习模型,其中80%用于训练、10%用于验证、10%用于测试。
  • 训练了两个模型:第一个使用所有标本(包括甲状腺)的自体荧光图像,第二个排除甲状腺以防止标本大小对结果的影响。

主要发现

  • 手术类型包括377例甲状旁腺切除术、239例全甲状腺切除术、97例甲状腺叶切除术和32例中央颈清扫术。
  • 数据集包含648张甲状旁腺、379张甲状腺、104张淋巴结和20张胸腺组织图像。
  • 模型检测甲状旁腺组织的总体精确率为96.5%,召回率为96.5%,曲线下面积为0.985。
  • 假阴性主要与颜色暗且体积大的甲状旁腺相关。

临床怎么用

  • 该模型可作为术中辅助工具,利用近红外自体荧光图像快速识别离体标本中的甲状旁腺组织。
  • 有望减少对冰冻切片和甲状旁腺激素抽吸的依赖,提高手术效率。

局限性

  • 假阴性主要与颜色暗且体积大的甲状旁腺相关,可能影响模型在这些情况下的可靠性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In thyroidectomy and parathyroidectomy procedures, diagnostic dilemmas related to whether an index tissue is of parathyroid or nonparathyroid origin frequently arise. Current options of frozen section and parathyroid aspiration are time-consuming. Parathyroid glands appear brighter than surrounding tissues on near-infrared autofluorescence imaging. The aim of this study was to develop an artificial intelligence model differentiating parathyroid tissue on surgical specimens based on near-infrared autofluorescence. METHODS: With institutional review board approval, an image library of ex vivo specimens obtained in thyroidectomy and parathyroidectomy procedures was created between November 2019 and April 2023 at a single academic center. Ex vivo autofluorescence images of surgically removed parathyroid glands, thyroid glands, lymph nodes, and thymic tissue were uploaded into an artificial intelligence platform. Two different models were trained, with the first model using autofluorescence images from all specimens, including thyroid, and the second model excluding thyroid, to prevent the effect of specimen size on the results. Deep-learning models were trained to detect autofluorescence signals specific to parathyroid glands. Randomly chosen 80% of data were used for training, 10% for validation, and 10% for testing. Recall, precision, and area under the curve of models were calculated. RESULTS: Surgical procedures included 377 parathyroidectomies, 239 total thyroidectomies, 97 thyroid lobectomies, and 32 central neck dissections. For the development of the model, 1151 images from a total of 678 procedures were used. The dataset comprised 648 parathyroid, 379 thyroid, 104 lymph node, and 20 thymic tissue images. The overall precision, recall, and area under the curve of the model to detect parathyroid tissue were 96.5%, 96.5%, and 0.985, respectively. False negatives were related to dark and large parathyroid glands. CONCLUSION: The visual deep-learning model developed to identify parathyroid tissue in ex vivo specimens during thyroidectomy and parathyroidectomy demonstrated a high sensitivity and positive predictive value. This suggests potential utility of near-infrared autofluorescence imaging to improve intraoperative efficiency by reducing the need for frozen sections and parathyroid hormone aspirations to confirm parathyroid tissue.

来源:Surgery,查看原文。版权归原作者所有。

引用

  1. Akgun E, Uysal M, Avci SN, et al. The use of artificial intelligence to detect parathyroid tissue on ex vivo specimens during thyroidectomy and parathyroidectomy procedures using near-infrared autofluorescence signals. Surgery. 2024. PMID: 39147664. doi:10.1016/j.surg.2024.07.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。