儿童经脐腹腔镜辅助阑尾切除术与标准三孔腹腔镜阑尾切除术的气候影响、临床结局与成本效益比较
结果显示TULAA+C的手术部位感染率未增加(1.3% vs 1.2%,p=0.81),每例成本更低(369.21美元 vs 879.30美元),碳排放更少(24.8 kg CO2e vs 27.4 kg CO2e)。
要点
- TULAA+C与LA的手术部位感染率无显著差异(1.3% vs 1.2%,p=0.81)。
- TULAA+C每例成本369.21美元,低于LA的879.30美元。
- TULAA+C每例碳排放24.8 kg CO2e,低于LA的27.4 kg CO2e。
核心结论
- 在临床非劣效性可证明时,应选择温室气体排放更少的治疗选项。
主要发现
- TULAA+C组手术部位感染15例(1.3%),LA组6例(1.2%),p=0.81。
- TULAA+C每例成本369.21美元,LA每例成本879.30美元。
- TULAA+C每例碳排放24.8千克二氧化碳当量,LA每例27.4千克二氧化碳当量。
- 除BMI外,两组间无临床显著差异。
关键数值与推荐
- 为检测手术部位感染增加≤2.5%,每组需至少479例患者以达到80%功效。
- 碳足迹根据国际标准化组织14067标准通过生命周期评估确定。
临床怎么用
- 在临床结局非劣效的前提下,可优先选择成本更低、碳排放更少的TULAA。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Healthcare is responsible for 8.5% of US greenhouse gas emissions. This impact must be mitigated while maintaining clinical excellence. This study compares clinical outcomes, cost-efficiency, and climate impact of transumbilical laparoscopic-assisted appendectomy (TULAA) vs 3-port laparoscopic appendectomy (LA). STUDY DESIGN: IRB approval was obtained. Appendectomies performed between January 1, 2020, and December 31, 2022, at a tertiary children's hospital were reviewed. Data abstracted included clinical characteristics, operative approach and findings, supplies and equipment used, and complication. For analysis, TULAA was combined with cases converted to LA (TULAA+C). To determine a surgical site infection increase of ≤2.5%, a minimum sample size of 479 patients per group was needed to achieve a power of 80%. A composite supply list for each approach was determined by averaging supplies from cases reviewed. The composite was used to calculate cost-efficiency and climate impact. Life cycle assessment was used to determine the carbon footprint (according to International Organization for Standardization standard 14067) of supplies and equipment. RESULTS: Analysis was performed on 1,611 appendectomies: 497 LA and 1,114 TULAA+C (932 TULAA and 182 converted). Except for BMI, there were no clinically significant differences between groups. Surgical site infection did not increase with TULAA+C (15, 1.3%) vs LA (6, 1.2%), p = 0.81. TULAA+C ($369.21 per case) was more cost-efficient than LA ($879.30 per case) and TULAA+C (24.8 kilograms of carbon dioxide equivalents) produced fewer emissions than LA (27.4 kilograms of carbon dioxide equivalents). CONCLUSIONS: Although patient safety and excellent clinical outcomes must remain the top priority in healthcare, the current environmental crisis demands consideration of climate impact. When clinical noninferiority can be demonstrated, treatment options with fewer greenhouse gas emissions should be chosen.
引用
- Fitzpatrick CM, Meinrenken CJ, Eimicke WB, et al. Comparison of Climate Impact, Clinical Outcomes, and Cost-Efficiency of Pediatric Transumbilical Laparoscopic-Assisted Appendectomy vs Standard 3-Port Laparoscopic Appendectomy. J Am Coll Surg. 2024. PMID: 39023165. doi:10.1097/XCS.0000000000001146
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。