电动圆形吻合器在择期结直肠手术中吻合口漏率升高的回顾性队列研究
该回顾性队列研究比较了择期左侧结直肠切除术中电动与手动圆形吻合器的吻合口漏率。手动组154例,电动组93例,总体漏率分别为2.0%和10.8%。电动吻合器漏的比值比为6.06(95%CI 1.62-22.65;p=0.01),结论与既往回顾性研究相反。
要点
- 电动圆形吻合器组吻合口漏率显著高于手动组(10.8% vs 2.0%)。
- 电动吻合器漏的比值比为6.06(95%CI 1.62-22.65;p=0.01)。
- 其他因素未发现与吻合口漏相关。
核心结论
- 左侧结直肠吻合使用电动圆形吻合器者吻合口漏率高于手动吻合器。
主要发现
- 手动组总体漏率为2.0%,电动组为10.8%。
- 电动吻合器漏的比值比为6.06(95%CI 1.62-22.65;p=0.01)。
- 其他因素未发现与吻合口漏相关。
临床怎么用
- 在左侧结直肠吻合中选用电动圆形吻合器时需警惕吻合口漏风险可能升高。
局限性
- 回顾性设计,两组手术时间跨度不同,样本量有限,可能存在未测量的混杂因素。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The objective of this study was to compare the anastomotic leak rates between powered and manual circular staplers in elective left-sided colorectal resections. METHODS: A retrospective cohort study of elective left-sided colorectal resections before and after implementation of a powered circular stapler at a tertiary care center was conducted. The manual stapler group consisted of consecutive resections performed between January 2016 to December 2016 and the powered stapler group, between September 2021 and December 2022. Primary outcome was 30-day anastomotic leak rate. A chi-squared analysis was performed to compare anastomotic leak rates. Factors associated with anastomotic leak were examined. RESULTS: Two-hundred forty-seven patients were included: 154 in the manual stapler group and 93 in the powered stapler group. Mean (SD) age was 60 (15) years old, 37.7% were female and 72.9% of resections were performed for malignancy. Both groups had similar patient characteristics and surgical technique. Overall leak rate was 2.0% in the manual stapler group and 10.8% in the powered stapler group. The powered staplers were found to have 6.06 times the odds of leak compared to manual staplers (95% CI, 1.62-22.65; p = 0.01). None of the other factors were found to be associated with anastomotic leak. CONCLUSIONS: Patients who had left-sided colorectal anastomosis had higher anastomotic leak rates with powered compared to manual circular staplers. This finding is contrary to previous retrospective studies that found lower leak rates with powered staplers.
引用
- Lie JJ, Samarasinghe N, Karimuddin AA, et al. Anastomotic leak rate following the implementation of a powered circular stapler in elective colorectal surgeries: a retrospective cohort study. Surg Endosc. 2024. PMID: 39060622. doi:10.1007/s00464-024-11082-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。