床边吻合器在机器人减重手术中的有效性
本研究基于PINC AI医疗数据,比较2021年机器人袖状胃切除或胃旁路术中床边吻合器(BS)与机器人吻合器(RS)的效果。共纳入7268例出院病例,其中BS组1603例(22.1%)、RS组5665例(77.9%)。校正分析显示RS组输血、ICU入住、手术时间延长(19分钟)和费用增加(1273美元)更显著,BS在效果相当的同时减少医疗资源利用。
要点
- 机器人减重手术中床边吻合器与机器人吻合器效果相当
- 床边吻合器可减少ICU入住、缩短手术时间并降低费用
- 两组输血率差异在敏感性分析中不显著
核心结论
- 床边吻合器在机器人减重手术中效果与机器人吻合器相当,且显著减少医疗资源利用并降低ICU入住。
研究设计与样本
- 回顾性队列研究,数据来源于PINC AI™ Healthcare Data,纳入2021年1月1日至12月31日期间接受机器人袖状胃切除或胃旁路择期手术的患者,共7268例出院病例,其中BS组1603例(22.1%)、RS组5665例(77.9%)。
主要发现
- RS组中西班牙裔患者比例更高(17.0% vs. 9.4%)、Medicaid覆盖比例更高(26.9% vs. 19.4%)、袖状胃切除比例更高(68.4% vs. 53.5%)。
- RS组更多由东北地区(35.5% vs. 24.3%)、床位少于500张(71.1% vs. 52.3%)及教学医院(59.4% vs. 39%)的提供者完成。
- 校正后RS组输血、ICU入住、手术时间延长(19分钟)和费用增加(1273美元)的风险显著更高。
- 敏感性分析结果类似,但两组输血率无显著差异。
临床怎么用
- 在机器人减重手术中可考虑使用床边吻合器以缩短手术时间、降低费用并减少ICU资源占用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Few studies have evaluated the use of laparoscopic staplers in robotic procedures (bedside stapling, BS). This study aims to evaluate the effectiveness of BS compared with robotic staplers (RS) in bariatric robotic procedures. METHODS: Patients who underwent robotic sleeve gastrectomy or gastric bypass elective procedures between 1/1/2021 and 12/31/2021 were extracted from PINC AI™ Healthcare Data. The following clinical outcomes were compared: blood transfusion, bleeding, anastomotic leak, intensive care unit (ICU) visit, and 30-day readmission, operating room (OR) time, inpatient costs, and length of stay. We evaluated baseline balance in BS and RS and bivariate association between covariates and outcomes using Chi-square or Fisher exact test and t-test or ANOVA. Multivariable general linear mixed models (GLMMs) with respective gamma or binomial distribution and log-link function were used to obtain adjusted outcomes variations between BS and RS. RESULTS: Total of 7268 discharges were included with 1603 (22.1%) BS and 5665 (77.9%) RS cases. RS cases consisted of a higher number of patients who were Hispanic (17.0% vs. 9.4%), had Medicaid (26.9% vs. 19.4%) and underwent sleeve gastrectomy (68.4% vs. 53.5%). Higher proportions of RS cases were done by providers in Northeast region (35.5% vs. 24.3%), smaller size (< 500 beds; 71.1% vs. 52.3%), and teaching hospitals (59.4% vs. 39%). The adjusted outcomes variations demonstrated that patients that had RS were significantly more likely to have blood transfusions, ICU stays, increased ORT (19 min) and costs ($1273). Sensitivity analysis showed similar results, except no significant differences in blood transfusion rates in both groups. CONCLUSIONS: Bedside staplers significantly reduce healthcare resource utilization with equivalent effectiveness and fewer ICU stays compared to robotic staplers.
引用
- Clapp BL, Billy H, Lutfi RE, et al. Effectiveness of bedside staplers in bariatric robotic procedures. Surg Endosc. 2024. PMID: 39020121. doi:10.1007/s00464-024-11045-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。