文献速递胃肠外科肝胆胰外科围术期管理与 ERAS

个体化包绕:食管裂孔疝修补术中应用功能性管腔成像探头(FLIP)

Tailoring the wrap: intraoperative functional lumen imaging probe (FLIP) during hiatal hernia repair.
PubMed 文献 · Surg Endosc · 2024-05-09

该单中心回顾性研究纳入2020至2022年33例接受非复发食管裂孔疝修补术并术中应用FLIP的患者,测量食管裂孔游离后、关闭后及必要时胃底折叠后的直径与扩张指数(DI)。DI最大下降出现在食管裂孔关闭后,胃底折叠后变化极小;13例(39%)术中决策受FLIP值直接影响。作者认为FLIP测量可用于术中指导决策,但需长期结局和进一步前瞻性研究明确其价值。

要点

  • 食管裂孔关闭后DI下降最明显,胃底折叠后变化极小。
  • 39%(13/33)的病例术中决策受FLIP值直接影响。
  • FLIP可指导胃底折叠的取舍、松紧和类型调整。

核心结论

  • FLIP测量可在术中使用,以客观值指导决策并改变处理方案。
  • 需要长期结局和进一步前瞻性研究来更好地界定该技术的价值。

研究设计与样本

  • 单中心回顾性研究,回顾2020至2022年电子病历,纳入所有接受非复发食管裂孔疝修补术并术中应用FLIP的患者。
  • 共33例患者符合纳入标准,平均年龄62±14岁,平均BMI 28±6 kg/m2,53%为I型食管裂孔疝。
  • 在食管裂孔游离后、食管裂孔关闭后及必要时胃底折叠后,分别于球囊充气40 ml和50 ml时测量直径和扩张指数(DI)。

主要发现

  • DI最大下降出现在食管裂孔关闭后,胃底折叠后变化极小(食管裂孔游离完成后平均DI为4.3±2,食管裂孔关闭后为2.7±1.2,行胃底折叠后为2.3±1)。
  • 13例(39%)术中决策受FLIP值直接影响。
  • 在13例中,4例(31%)暂缓胃底折叠,2例(15%)松解包绕,2例(15%)改变胃底折叠类型以达到 adequate 抗反流值,1例(3%)收紧包绕。

关键数值与推荐

  • DI测量条件为球囊充气40 ml和50 ml,时间点为食管裂孔游离后、食管裂孔关闭后及必要时胃底折叠后。
  • 原文未报告基于FLIP值的具体决策阈值。

临床怎么用

  • 作者认为FLIP测量可在术中使用,以客观值指导决策并改变处理方案。
  • 原文未据此给出具体推荐。

局限性

  • 原文未报告局限性。
  • 作者指出需要长期结局和进一步前瞻性研究来更好地界定该技术的价值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The introduction of the functional lumen imaging probe (FLIP) has provided objective, real-time feedback on the geometric variations with each component of a hiatal hernia repair (HHR). The utility of this technology in altering intraoperative decision-making has been scarcely reported. Herein, we report a single-center series of intraoperative FLIP during HHR. METHODS: A retrospective review of electronic medical records between 2020 and 2022 was conducted and all patients undergoing non-recurrent HHR with FLIP were queried. Patient and hernia characteristics, intraoperative FLIP values and changes in decision-making, as well as early post-operative outcomes were reported. Both diameter and distensibility index (DI) were measured at 40 ml and 50 ml balloon inflation after hiatal dissection, after hiatal closure, and after fundoplication when indicated. RESULTS: Thirty-three patients met inclusion criteria. Mean age was 62 ± 14 years and mean BMI was 28 ± 6 kg/m2. The majority (53%) were type I hiatal hernias. The largest drop in DI occurred after hiatal closure, with minimal change seen after fundoplication (mean DI of 4.3 ± 2. after completion of HH dissection, vs 2.7 ± 1.2 after hiatal closure and 2.3 ± 1 after fundoplication when performed). In 13 (39%) of cases, FLIP values directly impacted intraoperative decision-making. Fundoplication was deferred in 4/13 (31%) patients, the wrap was loosened in 2/13 (15%); the type of fundoplication was altered to achieve adequate anti-reflux values in 2/13 (15%) patients, and in 1/13 (3%) the wrap was tightened. CONCLUSION: FLIP measurements can be used intraoperatively to guide decision-making and alter management plan based on objective values. Long-term outcomes and further prospective studies are required to better delineate the value of this technology.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Alkhatib H, Haas AJ, Kara AM, et al. Tailoring the wrap: intraoperative functional lumen imaging probe (FLIP) during hiatal hernia repair. Surg Endosc. 2024. PMID: 38722379. doi:10.1007/s00464-024-10851-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。