人工智能在腹腔镜结肠切除术中实时检测活动性出血
研究从日本全国多机构手术视频数据库提取27段腹腔镜结肠切除术视频,按患者分为训练集21段、验证集3段、测试集3段,基于YOLOv7_6w开发实时检测活动性出血与积血的AI模型。模型对活动性出血的AP.50为0.574,处理速度48.5帧/秒,20名外科医生问卷的敏感度评分为4.92、过度检测评分为4.62。
要点
- 基于YOLOv7_6w开发AI模型,同时学习活动性出血与积血特征。
- 测试集活动性出血AP.50为0.574,处理速度达48.5帧/秒。
- 20名外科医生问卷敏感度评分4.92、过度检测评分4.62。
核心结论
- 研究开发了可实时检测活动性出血的AI模型,处理速度达到实时水平,作者认为该模型可用于提供实时手术支持。
研究设计与样本
- 从日本全国多机构手术视频数据库提取27段腹腔镜结肠切除术视频,按患者水平分为训练集21段、验证集3段、测试集3段。
- 逐帧标注活动性出血与积血,使用预训练YOLOv7_6w开发同时学习活动性出血和积血的模型。
- 量化活动性出血在交并比阈值0.5下的平均精度(AP.50)与每秒帧数(FPS),并用两项5点Likert量表问卷(5=优、4=良、3=中、2=差、1=失败)调查外科医生对敏感度和过度检测区域数量的评价。
主要发现
- 共标注254次出血事件的34,117张图像。
- 开发模型对活动性出血的AP.50为0.574,FPS为48.5。
- 20名外科医生回答两项问卷,模型敏感度评分为4.92,过度检测评分为4.62。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Most intraoperative adverse events (iAEs) result from surgeons' errors, and bleeding is the majority of iAEs. Recognizing active bleeding timely is important to ensure safe surgery, and artificial intelligence (AI) has great potential for detecting active bleeding and providing real-time surgical support. This study aimed to develop a real-time AI model to detect active intraoperative bleeding. METHODS: We extracted 27 surgical videos from a nationwide multi-institutional surgical video database in Japan and divided them at the patient level into three sets: training (n = 21), validation (n = 3), and testing (n = 3). We subsequently extracted the bleeding scenes and labeled distinctively active bleeding and blood pooling frame by frame. We used pre-trained YOLOv7_6w and developed a model to learn both active bleeding and blood pooling. The Average Precision at an Intersection over Union threshold of 0.5 (AP.50) for active bleeding and frames per second (FPS) were quantified. In addition, we conducted two 5-point Likert scales (5 = Excellent, 4 = Good, 3 = Fair, 2 = Poor, and 1 = Fail) questionnaires about sensitivity (the sensitivity score) and number of overdetection areas (the overdetection score) to investigate the surgeons' assessment. RESULTS: We annotated 34,117 images of 254 bleeding events. The AP.50 for active bleeding in the developed model was 0.574 and the FPS was 48.5. Twenty surgeons answered two questionnaires, indicating a sensitivity score of 4.92 and an overdetection score of 4.62 for the model. CONCLUSIONS: We developed an AI model to detect active bleeding, achieving real-time processing speed. Our AI model can be used to provide real-time surgical support.
引用
- Horita K, Hida K, Itatani Y, et al. Real-time detection of active bleeding in laparoscopic colectomy using artificial intelligence. Surg Endosc. 2024. PMID: 38760565. doi:10.1007/s00464-024-10874-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。