文献速递甲状腺与颈部外科

全甲状腺切除术中是否使用近红外自体荧光成像对病理检出偶发甲状旁腺组织检出率的比较

Comparison of incidental parathyroid tissue detection rates on pathology after total thyroidectomy performed with or without near-infrared autofluorescence imaging.
PubMed 文献 · Surgery · 2023-10-20

单中心回顾性研究比较2014至2022年全甲状腺切除术患者,使用近红外自体荧光(NIRAF)组300例与非NIRAF组750例的病理偶发甲状旁腺组织检出率,分别为13.3%(n=40)与23.2%(n=174)(P<.001)。NIRAF同时用于识别和确认时检出率由30.0%降至13.4%(P<.001),仅用于确认时无显著变化(19.6%至18.5%,P=.89)。作者认为NIRAF同时用于识别和确认可能有助于降低偶发甲状旁腺组织检出率。

要点

  • NIRAF组病理偶发甲状旁腺组织检出率为13.3%(n=40),非NIRAF组为23.2%(n=174),P<.001。
  • NIRAF同时用于识别和确认时检出率由30.0%降至13.4%(P<.001)。
  • NIRAF仅用于确认时检出率由19.6%至18.5%(P=.89),无显著变化。

核心结论

  • 作者认为全甲状腺切除术中使用近红外自体荧光同时用于甲状旁腺识别和确认,可能有助于降低最终病理检出的偶发甲状旁腺组织率。

研究设计与样本

  • 单中心回顾性研究,纳入2014年至2022年接受全甲状腺切除术的患者,比较NIRAF组(300例)与非NIRAF组(750例)的临床参数,包括病理报告偶发甲状旁腺组织检出率。
  • NIRAF用于引导分离(识别)和/或确认组织为甲状旁腺(确认),统计分析采用Wilcoxon秩和检验和χ2分析。

主要发现

  • 最终病理偶发甲状旁腺组织检出率NIRAF组为13.3%(n=40),非NIRAF组为23.2%(n=174),P<.001。
  • NIRAF同时用于识别和确认甲状旁腺组织时,病理偶发甲状旁腺组织检出率由30.0%降至13.4%(P<.001)。
  • NIRAF仅用于确认时,检出率由19.6%至18.5%(P=.89),无显著变化。
  • NIRAF降低偶发甲状旁腺组织检出率的作用在早期职业外科医生中更明显(38.5%降至17.1%),中晚期职业外科医生为20%降至13%。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Near-infrared autofluorescence imaging is an adjunct to parathyroid identification. As it does not show perfusion, it is important to study its impact during thyroidectomy by measuring quantifiable data on parathyroid detection rather than function. The aim of this study was to compare incidental parathyroidectomy rates in patients undergoing total thyroidectomy with or without near-infrared autofluorescence. METHODS: Retrospective study of patients who underwent total thyroidectomy between 2014 and 2022 at one center. Clinical parameters, including rates of incidental parathyroid tissue on pathology reports, were compared between near-infrared autofluorescence and non-near-infrared autofluorescence groups. Near-infrared autofluorescence was used to guide dissection (identification) and/or to confirm tissue as parathyroid (confirmation). Statistical analysis was done with Wilcoxon rank sum test and χ2 analysis. RESULTS: There were 300 patients in the near-infrared autofluorescence and 750 patients in the non-near-infrared autofluorescence group. The rate of incidental parathyroid tissue detection on final pathology was 13.3% (n = 40) in the near-infrared autofluorescence and 23.2% (n = 174) in the non-near-infrared autofluorescence group (P < .001). The rate of incidental parathyroid tissue detected on pathology with near-infrared autofluorescence decreased when used for identification and confirmation of parathyroid tissue (30.0% to 13.4%, P < .001), but not when used for confirmation only (19.6% to 18.5%, P = .89). Impact of near-infra red autofluorescence in decreasing the rate of incidental parathyroid tissue was more profound for early (38.5% to 17.1%) versus mid-late career surgeons (20% to 13%). CONCLUSION: Our results suggest that the use of near-infrared autofluorescence may help decrease the rate of incidental parathyroid tissue detected on final pathology if used for both identification and confirmation of parathyroid glands during thyroidectomy.

来源:Surgery,查看原文。版权归原作者所有。

引用

  1. Romero-Velez G, Avci SN, Isiktas G, et al. Comparison of incidental parathyroid tissue detection rates on pathology after total thyroidectomy performed with or without near-infrared autofluorescence imaging. Surgery. 2023. PMID: 37867101. doi:10.1016/j.surg.2023.05.047

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。