文献速递甲状腺与颈部外科

倾向性评分匹配分析:无充气腋窝入路内镜甲状腺切除术五定点技术与传统开放甲状腺切除术在甲状腺微小乳头状癌患者中的比较

A propensity score matching analysis of gasless endoscopic transaxillary thyroidectomy with five-settlement technique versus conventional open thyroidectomy in patients with papillary thyroid microcarcinoma.
PubMed 文献 · Surg Endosc · 2023-10-24

本研究回顾性纳入2019年2月至2021年12月由同一术者行无充气腋窝入路内镜甲状腺切除术五定点技术(fs-TAT)或传统开放甲状腺切除术(COT)的甲状腺微小乳头状癌患者,经倾向性评分匹配后每组230例。fs-TAT组手术时间更长、术后总引流量更多,但COT组术中出血更多、淋巴结检出中位数更多;两组并发症率、阳性淋巴结率、术后住院时间和总医疗费用无显著差异。作者认为fs-TAT在经选择的甲状腺微小乳头状癌患者中安全性和短期肿瘤学结局可接受。

要点

  • fs-TAT组手术时间104.5分钟 vs COT组62.0分钟,P<0.001。
  • fs-TAT组术后总引流量135 mL vs COT组75 mL,P<0.001。
  • 两组并发症率2.2% vs 2.6%、阳性淋巴结率32.2% vs 36.5%,均无显著差异。

核心结论

  • 与COT相比,fs-TAT在经选择的甲状腺微小乳头状癌患者中提供了良好的安全性和可接受的短期肿瘤学结局。

研究设计与样本

  • 回顾性综述单个术者2019年2月至2021年12月收治的甲状腺微小乳头状癌患者的病历资料,所有患者均行腺叶切除及同侧中央区颈淋巴结清扫。
  • 采用倾向性评分匹配比较fs-TAT与COT的技术安全性和短期肿瘤学结局,以减少潜在选择偏倚。
  • 报告遵循STROCSS 2021指南,倾向性评分匹配后共460例(fs-TAT组230例,COT组230例)纳入研究人群。

主要发现

  • 匹配后两组在性别、年龄、肿瘤大小、桥本甲状腺炎及肿瘤多灶性方面无显著差异。
  • fs-TAT组手术时间长于COT组[104.5(90.3,120.0) vs 62.0(52.0,76.0),P<0.001],术后总引流量大于COT组[135(90,210) vs 75(55,115),P<0.001]。
  • COT组术中出血量大于fs-TAT组[5.0(5.0,7.5) vs 3.0(2.0,5.0),P<0.001],淋巴结检出中位数多于fs-TAT组[7.0(5.0,11.0) vs 5.0(2.3,8.0),P<0.001]。
  • 两组并发症率(fs-TAT组2.2% vs COT组2.6%,P=0.856)、阳性淋巴结率(fs-TAT组32.2% vs COT组36.5%,P=0.377)、术后住院时间(3天 vs 3天,P=0.305)及总医疗费用(26,936 vs 26,549,P=0.144)均无显著差异。

临床怎么用

  • 作者认为,与COT相比,fs-TAT在经选择的甲状腺微小乳头状癌患者中安全性和短期肿瘤学结局可接受。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In a previous study, we proposed a novel anatomy-based five-settlement method for transaxillary endoscopic thyroidectomy (fs-TAT) for patients with papillary thyroid carcinoma. The safety of this new method has been reported in a retrospective study of a single cohort. The safety and short-term oncological outcome of this method was confirmed by comparing it with conventional open surgery (COT) in patients with papillary thyroid microcarcinoma. METHODS: The medical records of patients who underwent fs-TAT or COT by a single surgeon from February 2019 to December 2021 were reviewed retrospectively. All patients were diagnosed with papillary thyroid microcarcinoma and underwent lobectomy and ipsilateral central compartment neck dissection. Propensity score matching was used to compare the technical safety and short-term oncologic outcomes of fs-TAT and COT for the purpose of reducing potential selection bias. Reporting was consistent with the STROCSS 2021 guidelines. RESULT: After propensity score matching, 460 (fs-TAT: 230; COT: 230) patients remained in the study population. There were no significant differences in sex, age, tumor size, Hashimoto's thyroiditis, or tumor multifocality between the groups. The operative time was longer [104.5 (90.3, 120.0) vs. 62.0 (52.0, 76.0), P < 0.001] and the total postoperative drainage volume [135(90, 210) vs. 75 (55, 115), P < 0.001] was greater in the fs-TAT group than in the COT group. However, intraoperative bleeding [3.0 (2.0, 5.0) vs. 5.0 (5.0, 7.5), P < 0.001] was greater, and the median number of lymph nodes yielded [5.0 (2.3, 8.0) vs. 7.0 (5.0, 11.0), P < 0.001] was greater in the COT group than in the fs-TAT group. The groups exhibited no significant difference in the rate of complications (fs-TAT: 2.2% vs. COT: 2.6%, P = 0.856), rate of positive lymph nodes (fs-TAT: 32.2% vs. COT: 36.5%, P = 0.377), length of postoperative hospital stay (3 days vs. 3 days, P = 0.305) or total medical costs (26,936 vs. 26,549, P = 0.144). CONCLUSION: Compared to conventional open surgery, fs-TAT offered excellent safety and acceptable short-term oncological outcomes in a selected cohort of patients with papillary thyroid microcarcinoma.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Ge JN, Yu ST, Tan J, et al. A propensity score matching analysis of gasless endoscopic transaxillary thyroidectomy with five-settlement technique versus conventional open thyroidectomy in patients with papillary thyroid microcarcinoma. Surg Endosc. 2023. PMID: 37875693. doi:10.1007/s00464-023-10473-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。