文献速递胃肠外科疝与腹壁外科围术期管理与 ERAS

一种用于腹腔镜完全腹膜外腹股沟疝修补术(TEP)中人工智能自动手术流程识别的新型高精度模型

A novel high accuracy model for automatic surgical workflow recognition using artificial intelligence in laparoscopic totally extraperitoneal inguinal hernia repair (TEP).
PubMed 文献 · Surg Endosc · 2023-08-25

本研究利用619段TEP手术视频训练并验证首个AI计算机视觉算法,自动识别手术六大步骤;整体准确率为88.8%,疝囊还纳步骤准确率最高(94.3%),腹膜前分离步骤最低(72.2%);结论认为该模型能以高准确率实现全自动视频分析。

要点

  • 619段TEP视频中371段用于训练、93段用于内部验证、155段作为测试集。
  • 完整手术流程整体准确率为88.8%。
  • 分步骤准确率最高为疝囊还纳步骤94.3%,最低为腹膜前分离步骤72.2%。

核心结论

  • 该新型AI模型能够以高准确率水平提供全自动视频分析。
  • 高准确率的AI模型可实现手术视频分析自动化,识别和监测手术表现,提供可存储、评估和比较的数学指标。
  • 所提出的模型能够实现数据驱动的洞察,以改善手术质量并展示TEP手术的最佳实践。

研究设计与样本

  • 由经过培训的标注团队按照六个主要步骤手动标注TEP手术视频中的手术流程,双侧疝额外包括一个改变聚焦步骤。
  • 使用标注视频训练计算机视觉AI算法,并与手动标注比较评估性能准确率。
  • 共分析619段完整TEP视频:371段用于训练模型,93段用于内部验证,其余155段作为测试集评估算法准确率。

主要发现

  • 完整手术流程的整体准确率为88.8%。
  • 分步骤准确率最高为疝囊还纳步骤94.3%。
  • 分步骤准确率最低为腹膜前分离步骤72.2%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Artificial intelligence and computer vision are revolutionizing the way we perceive video analysis in minimally invasive surgery. This emerging technology has increasingly been leveraged successfully for video segmentation, documentation, education, and formative assessment. New, sophisticated platforms allow pre-determined segments chosen by surgeons to be automatically presented without the need to review entire videos. This study aimed to validate and demonstrate the accuracy of the first reported AI-based computer vision algorithm that automatically recognizes surgical steps in videos of totally extraperitoneal (TEP) inguinal hernia repair. METHODS: Videos of TEP procedures were manually labeled by a team of annotators trained to identify and label surgical workflow according to six major steps. For bilateral hernias, an additional change of focus step was also included. The videos were then used to train a computer vision AI algorithm. Performance accuracy was assessed in comparison to the manual annotations. RESULTS: A total of 619 full-length TEP videos were analyzed: 371 were used to train the model, 93 for internal validation, and the remaining 155 as a test set to evaluate algorithm accuracy. The overall accuracy for the complete procedure was 88.8%. Per-step accuracy reached the highest value for the hernia sac reduction step (94.3%) and the lowest for the preperitoneal dissection step (72.2%). CONCLUSIONS: These results indicate that the novel AI model was able to provide fully automated video analysis with a high accuracy level. High-accuracy models leveraging AI to enable automation of surgical video analysis allow us to identify and monitor surgical performance, providing mathematical metrics that can be stored, evaluated, and compared. As such, the proposed model is capable of enabling data-driven insights to improve surgical quality and demonstrate best practices in TEP procedures.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Ortenzi M, Rapoport Ferman J, Antolin A, et al. A novel high accuracy model for automatic surgical workflow recognition using artificial intelligence in laparoscopic totally extraperitoneal inguinal hernia repair (TEP). Surg Endosc. 2023. PMID: 37626236. doi:10.1007/s00464-023-10375-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。