左半结肠与直肠癌手术中评估肠管灌注的吲哚菁绿荧光发射所需时间
本研究回顾性纳入217例2018年11月至2022年7月在本院接受左半结肠与直肠癌手术并用吲哚菁绿荧光成像评估灌注的患者,记录注射后达最大荧光发射所需时间。吻合口漏组中位时间32秒(范围25-58秒)长于非吻合口漏组28秒(范围10-45秒),P<0.001;ROC曲线得出的吻合口漏判断界值为31秒。结论认为ICG荧光发射所需时间与吻合口漏相关。
要点
- 217例中吻合口漏发生21例(9.7%)。
- 吻合口漏组ICG达最大荧光时间中位32秒,非吻合口漏组28秒,P<0.001。
- ROC曲线得出的吻合口漏界值为31秒。
核心结论
- ICG荧光发射所需时间与左半结肠和直肠癌手术后吻合口漏相关。
研究设计与样本
- 回顾性研究,纳入2018年11月至2022年7月在本院接受左半结肠与直肠癌手术并使用ICG荧光成像评估灌注的217例结直肠癌患者。
主要发现
- 217例中吻合口漏发生21例(9.7%)。
- ICG给药至最大荧光发射的中位时间在吻合口漏组为32秒(范围25-58秒),在非吻合口漏组为28秒(范围10-45秒),P<0.001。
- ROC曲线得出的吻合口漏界值为31秒。
- 在58例ICG荧光所需时间≥31秒的患者中,吻合口漏的危险因素包括:术前白蛋白较低[3.4 mg/dl(范围2.6-4.4)vs. 3.9 mg/dl(范围2.6-4.9),P=0.016]、未行术前机械性肠道准备(53.8% vs. 91.1%,P=0.005)、梗阻性肿瘤(61.5% vs. 17.8%,P=0.004)及肿瘤直径较大[65 mm(范围40-90)vs. 35 mm(范围4.0-100),P<0.001]。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Indocyanine green fluorescence imaging (ICG-FI) has been reported to be useful in reducing the incidence of anastomotic leakage (AL) in colectomy. This study aimed to investigate the correlation between the required time for ICG fluorescence emission and AL in left-sided colon and rectal cancer surgery using the double-stapling technique (DST) anastomosis. METHODS: This retrospective study included 217 patients with colorectal cancer who underwent left-sided colon and rectal surgery using ICG-FI-based perfusion assessment at our department between November 2018 and July 2022. We recorded the time required to achieve maximum fluorescence emission after ICG systemic injection and assessed its correlation with the occurrence of AL. RESULTS: Among 217 patients, AL occurred in 21 patients (9.7%). The median time from ICG administration to maximum fluorescence emission was 32 s (range 25-58 s) in the AL group and 28 s (range 10-45 s) in the non-AL group (p < 0.001). The cut-off value for the presence of AL obtained from the ROC curve was 31 s. In 58 patients with a required time for ICG fluorescence of 31 s or longer, the following risk factors for AL were identified: low preoperative albumin [3.4 mg/dl (range 2.6-4.4) vs. 3.9 mg/dl (range 2.6-4.9), p = 0.016], absence of preoperative mechanical bowel preparation (53.8% vs. 91.1%, p = 0.005), obstructive tumor (61.5% vs. 17.8%, p = 0.004), and larger tumor diameter [65 mm (range 40-90) vs. 35 mm (range 4.0-100), p < 0.001]. CONCLUSION: The time required for ICG fluorescence emission was associated with AL.
引用
- Hagiwara C, Wakabayashi T, Tsutsui A, et al. Time required for indocyanine green fluorescence emission for evaluating bowel perfusion in left-sided colon and rectal cancer surgery. Surg Endosc. 2023. PMID: 37640952. doi:10.1007/s00464-023-10356-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。