抽吸校准系统能否减少吻合器钉仓使用次数和手术时间?一项比较内镜校准与抽吸校准在腹腔镜袖状胃切除术中应用的随机对照试验

Does the use of a suction calibration system (SCS) reduce stapler load firings and operative time? A randomized controlled trial comparing use of endoscopic calibration vs. SCS in laparoscopic sleeve gastrectomy.
PubMed 文献 · Surg Endosc · 2023-07-11

该单中心随机对照试验纳入125例接受腹腔镜袖状胃切除术的患者,比较内镜与抽吸校准系统对吻合器钉仓使用次数的影响。结果显示两组钉仓使用次数(5.43 vs 5.31,p=0.463)和手术时间(94.4 vs 93.1 min,p=0.83)均无显著差异,术后反流、总体重变化及并发症也无显著差异。

要点

  • 抽吸校准系统与内镜校准在减少钉仓使用次数上无显著差异。
  • 两组手术时间、术后反流和总体重变化无显著差异。
  • 仍需在不同患者和场景中比较校准装置以优化手术技术。

核心结论

  • 使用内镜或抽吸校准系统进行腹腔镜袖状胃切除术,吻合器钉仓使用次数和手术时间相似。

研究设计与样本

  • 单中心、随机、非盲法研究,纳入125例接受腹腔镜袖状胃切除术的患者(84%女性,平均年龄44±12岁,平均BMI 49±8 kg/m2),其中117例随机分配至内镜组(n=59)或抽吸校准系统组(n=58)。

主要发现

  • 内镜组和抽吸校准系统组的平均吻合器钉仓使用次数分别为5.43±0.89和5.31±0.81(p=0.463)。
  • 内镜组和抽吸校准系统组的平均手术时间分别为94.4±36.5和93.1±27.9分钟(p=0.83)。
  • 两组在术后反流、总体重变化或并发症方面无显著差异。

临床怎么用

  • 在腹腔镜袖状胃切除术中,内镜和抽吸校准系统均可用于校准,两者在钉仓使用次数和手术时间上效果相似。

局限性

  • 研究为单中心、非盲法设计,可能影响结果的外推性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: It is critical to ensure appropriate and consistent sleeve size and orientation during laparoscopic sleeve gastrectomy (LSG). Various devices are used to achieve this, including weighted rubber bougies, esophagogastroduodenoscopy (EGD), and suction calibration systems (SCS). Prior reports suggest that SCSs may decrease operative time and stapler load firings but are limited by single-surgeon experience and retrospective design. We performed the first randomized controlled trial comparing SCS against EGD in patients undergoing LSG to investigate whether the SCS decreases the number of stapler load firings. METHODS: This was a randomized, non-blinded study from a single MBSAQIP-accredited academic center. Appropriate LSG candidates ≥ 18 years of age were randomized to EGD or SCS calibration. Exclusion criteria included prior gastric or bariatric surgery, detection of hiatal hernia before surgery, and intraoperative hiatal hernia repair. A randomized block design was employed controlling for body mass index, gender, and race. Seven surgeons employed a standardized LSG operative technique. The primary endpoint was the number of stapler load firings. Secondary endpoints were operative duration, reflux symptoms, and change in total body weight (TBW). Endpoints were analyzed via t-test. RESULTS: A total of 125 LSG patients (84% female) underwent study enrollment, with an average age of 44 ± 12 years and average BMI of 49 ± 8 kg/m2. Overall, 117 patients were randomized to receive EGD (n = 59) or SCS (n = 58) calibration. No significant differences in baseline characteristics were identified. The mean number of stapler load firings for EGD and SCS groups were 5.43 ± 0.89 and 5.31 ± 0.81, respectively (p = 0.463). The mean operative times for EGD and SCS groups were 94.4 ± 36.5 and 93.1 ± 27.9 min, respectively (p = 0.83). There were no significant differences in post-operative reflux, TBW loss, or complications. CONCLUSION: Use of EGD and SCS resulted in a similar number of LSG stapler load firings and operative duration. Additional research is needed to compare LSG calibration devices in different patients and settings to optimize surgical technique.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Hechenbleikner E, Mou D, Delgado V, et al. Does the use of a suction calibration system (SCS) reduce stapler load firings and operative time? A randomized controlled trial comparing use of endoscopic calibration vs. SCS in laparoscopic sleeve gastrectomy. Surg Endosc. 2023. PMID: 37433914. doi:10.1007/s00464-023-10251-2