机器人对比腹腔镜腹壁切口疝修补术:前瞻性多中心盲法随机临床试验两年结果
该多中心随机对照试验比较机器人对比腹腔镜腹腔内补片置入腹壁疝修补术的两年结局。共124例随机分组,101例完成两年随访。机器人组疝复发2例(4%)对比腹腔镜组6例(13%),差异无统计学意义(P=0.12);机器人组无再手术(0%),腹腔镜组5例(11%)再手术(P=0.019)。结论认为机器人修补至少不劣于腹腔镜,需更多多中心试验验证。
要点
- 两年随访中机器人组疝复发4%、腹腔镜组13%,差异无统计学意义。
- 机器人组无再手术,腹腔镜组再手术率11%,差异有统计学意义。
- 手术部位感染和手术部位occurrence两组无差异。
核心结论
- 机器人腹壁疝修补术两年结局至少与腹腔镜相似,可能存在获益,但需更多多中心试验和更长随访验证。
研究设计与样本
- 前瞻性、多中心、盲法随机对照试验,注册号NCT03490266,比较机器人对比腹腔镜腹腔内补片置入腹壁疝修补术。
- 共124例随机分组,101例完成两年随访,机器人组54例(83%)、腹腔镜组47例(80%)完成随访。
主要发现
- 手术部位感染和手术部位occurrence两组无差异。
- 疝复发机器人组2例(4%)对比腹腔镜组6例(13%),相对风险0.3(95%CI 0.06-1.39),P=0.12。
- 再手术机器人组0例(0%)对比腹腔镜组5例(11%),P=0.019,因零结局相对风险不可计算。
关键数值与推荐
- 疝复发相对风险0.3(95%CI 0.06-1.39),P=0.12。
- 再手术比较P=0.019。
临床怎么用
- 机器人腹壁疝修补可作为腹腔镜的替代选择,两年复发和再手术结局至少不劣于腹腔镜。
局限性
- 两年随访完成率机器人组83%、腹腔镜组80%,存在失访。
- 样本量较小(随机124例),结论需更多多中心试验和更长随访验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Report the 2-year outcomes of a multicenter randomized controlled trial comparing robotic versus laparoscopic intraperitoneal onlay mesh ventral hernia repair. BACKGROUND: Ventral hernia repair is one of the most common operations performed by general surgeons. To our knowledge, no studies have been published to date comparing long-term outcomes of laparoscopic versus robotic ventral hernia repair. METHODS: The trial was registered at clinicaltrials.gov (NCT03490266). Clinical outcomes included surgical site infection, surgical site occurrence, hernia occurrence, readmission, reoperation, and mortality. RESULTS: A total of 175 consecutive patients were approached that were deemed eligible for elective minimally invasive ventral hernia repair. In all, 124 were randomized and 101 completed follow-up at 2 years. Two-year follow-up was completed in 54 patients (83%) in the robotic arm and 47 patients (80%) in the laparoscopic arm. No differences were seen in surgical site infection or surgical site occurrence. Hernia recurrence occurred in 2 patients (4%) receiving robotic repair versus in 6 patients (13%) receiving laparoscopic repair (relative risk: 0.3, 95% CI: 0.06-1.39; P =0.12). No patients (0%) required reoperation in the robotic arm whereas 5 patients (11%) underwent reoperation in the laparoscopic arm ( P =0.019, relative risk not calculatable due to null outcome). CONCLUSIONS: Robotic ventral hernia repair demonstrated at least similar if not improved outcomes at 2 years compared with laparoscopy. There is potential benefit with robotic repair; however, additional multi-center trials and longer follow-up are needed to validate the hypothesis-generating findings of this study.
引用
- Dhanani NH, Lyons NB, Olavarria OA, et al. Robotic Versus Laparoscopic Ventral Hernia Repair: Two-Year Results From a Prospective, Multicenter, Blinded Randomized Clinical Trial. Ann Surg. 2023. PMID: 37203558. doi:10.1097/SLA.0000000000005903
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。