亚甲蓝同步荧光成像评估肠灌注与输尿管显影的猪模型研究
本研究在6只Landrace猪中评估使用单一近红外荧光成像系统同步实现肠灌注和输尿管显影的可行性。静脉注射吲哚菁绿(ICG)0.2 mg/kg评估肠灌注,亚甲蓝(MB)静脉注射0.75、0.50或0.25 mg/kg用于输尿管显影。结果显示所有动物均成功实现输尿管显影和肠灌注成像,MB也可用于肠灌注评估,且ICG与MB无相互干扰,MB冲洗更快。
要点
- 单系统可同步实现ICG肠灌注和MB输尿管显影
- MB也可用于肠灌注评估,且冲洗更快,可能支持重复注射
核心结论
- 使用同一商用近红外荧光成像系统可同步实现ICG肠灌注血管造影和MB输尿管显影。
- MB适用于该系统的肠灌注评估和输尿管显影,且冲洗时间更早,可能有利于术中重复注射。
研究设计与样本
- 实验研究,6只Landrace猪在全身麻醉下接受剖腹术。
- 静脉注射ICG 0.2 mg/kg评估肠灌注;两对猪分别接受MB静脉注射0.75、0.50或0.25 mg/kg以研究输尿管显影。
- 使用Quest Spectrum荧光相机(Quest Medical Imaging, Middenmeer, The Netherlands)进行近红外荧光成像。
主要发现
- 所有动物均实现输尿管显影和肠灌注的近红外荧光成像。
- 混合模型分析未显示三组之间或随时间变化有显著差异。
- 肠灌注也可用MB显影;未观察到ICG与MB之间的干扰,且MB冲洗更快。
临床怎么用
- 在结直肠手术中,可考虑使用单一近红外荧光成像系统同步评估肠灌注和输尿管显影。
- MB可作为输尿管显影和肠灌注评估的荧光染料,其较早冲洗可能支持术中重复注射。
局限性
- 研究仅在小样本猪模型中进行,尚未在人体验证。
- 未报告统计学显著差异的具体数值,组间比较无显著差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Intraoperative near-infrared fluorescence imaging (NIRF) with preoperative optical dye administration is a promising technique for quick and easy intraoperative visualization of the ureter and for an improved, real-time assessment of intestinal perfusion. During colorectal surgery, there is a need for simultaneous non-invasive ureteral imaging and bowel perfusion assessment, using one single camera system. The purpose of this study is to investigate the feasibility of simultaneous intestinal perfusion and ureteral imaging using a single commercially available NIRF imaging system. METHODS: Six Landrace pigs underwent laparotomy under general anesthesia in this experiment. An intravenous (IV) dose of 0.2 mg/kg indocyanine green (ICG) was given to assess bowel perfusion. Two pairs received a methylene blue (MB) iv injection of 0.75, 0.50 or 0.25 mg/kg respectively to investigate ureteral visualization. Quest Spectrum Fluorescence Camera (Quest Medical Imaging, Middenmeer, The Netherlands) was used for NIRF imaging. RESULTS: Ureter visualization and bowel perfusion under NIRF imaging was achieved in all animals. All ureters were visible after five to ten minutes and remained clearly visible until the end of every experiment (120-420 min). A mixed model analysis did not show any significant differences neither between the three groups nor over time. Importantly, we demonstrated that bowel perfusion could be visualized with methylene blue (MB) as well. We observed no interference between ICG and MB and a faster washout of MB. CONCLUSION: We successfully demonstrated simultaneous fluorescence angiography with ICG and ureteral imaging with MB in the same surgical procedure, with the same commercially available NIRF imaging equipment. More importantly, we showed that the use MB is adequate for bowel perfusion assessment and ureter visualization with this NIRF imaging system. Besides, MB showed an earlier washout time, which can be clinical beneficial as a repeated dye injection may be necessary during a surgical procedure.
引用
- Heuvelings DJI, Al-Difaie Z, Scheepers MHMC, et al. Simultaneous fluorescence imaging of bowel perfusion and ureter delineation using methylene blue: a demonstration in a porcine model. Surg Endosc. 2023. PMID: 37253870. doi:10.1007/s00464-023-10142-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。