腹腔镜镜头清洁装置对结直肠手术多维工作负荷影响的随机对照试验
本研究通过随机对照试验评估OpClear®腹腔镜镜头清洁装置对结直肠癌腹腔镜手术术者多维工作负荷的影响。共120例患者随机分配至温盐水组或OpClear®组,最终116例纳入分析。结果显示两组总体工作负荷无显著差异,但OpClear®组体力需求及腔外镜头清洗次数显著降低。
要点
- OpClear®组与温盐水组总体SURG-TLX工作负荷无显著差异。
- OpClear®组体力需求评分显著低于温盐水组(6 vs 7,p=0.046)。
- OpClear®组腔外镜头清洗次数显著少于温盐水组(2 vs 10,p<0.001)。
核心结论
- 总体工作负荷无显著差异,但OpClear®组体力需求和腔外镜头清洗次数显著降低。
研究设计与样本
- 随机对照试验,纳入120例拟行腹腔镜结直肠癌手术患者,最终116例分析(温盐水组59例,OpClear®组57例)。
主要发现
- SURG-TLX总体工作负荷两组无显著差异。
- OpClear®组体力需求显著低于温盐水组(6 vs 7,p=0.046)。
- OpClear®组腔外镜头清洗总次数显著少于温盐水组(2 vs 10,p<0.001)。
- 两组手术时间相似。
临床怎么用
- 使用OpClear®装置可能有助于降低术者体力需求相关的压力。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: OpClear® is a newly developed laparoscopic lens-cleaning device that can be attached to a laparoscope. The present study determined whether or not the use of a OpClear® reduces the multidimensional surgery-specific workload of the operator during laparoscopic colorectal surgery for colorectal cancer compared with the reference technique (warm saline) by a randomized controlled trial. METHODS: Patients diagnosed with colorectal cancer and scheduled for laparoscopic colorectal surgery were randomly allocated to the warm saline arm or Opclear® arm. The primary endpoint was the multidimensional workload of the first operator (value of SURG-TLX). The secondary endpoints were the operative time and total number of lens washes outside the abdominal cavity. RESULTS: Between March 2020 and January 2021, a total of 120 patients were enrolled in this study. A total of 4 patients were excluded from the full analysis set. A total of 116 patients (warm saline arm: 59 patients, Opclear® arm: 57 patients) were therefore analyzed. The baseline factors were well-balanced between the two arms. Regarding SURG-TLX, there was no significant difference in the overall workload between the two arms. Operators in the Opclear® arm required significantly less physical demand than in the warm saline arm (Opclear® arm: 6, warm saline arm: 7; p = 0.046). The operative time was similar between the two arms. The total number of lens washes outside the abdominal cavity in the Opclear® arm was significantly lower than that in the warm saline arm (Opclear® arm: 2, warm saline arm: 10; p < 0.001). CONCLUSIONS: There was no significant difference in the overall workload, but the physical demand and total number of lens washes outside the abdominal cavity were significantly lower in the Opclear® arm than in the warm saline arm. The use of this device may thus help reduce operator stress in terms of physical demand. The study was registered with the Japanese Clinical Trials Registry as UMIN0000038677.
引用
- Watanabe J, Suwa Y, Goto K, et al. Randomized controlled trial evaluating the effect of the use of a laparoscopic lens-cleaning device during laparoscopic colorectal surgery on the multidimensional workload (YCOG1903). Surg Endosc. 2023. PMID: 36894809. doi:10.1007/s00464-023-09972-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。