文献速递胃肠外科围术期管理与 ERAS

机器人辅助低位前切除术中吲哚菁绿评估吻合口灌注:观察者间差异的多中心研究

Anastomotic perfusion assessment with indocyanine green in robot-assisted low-anterior resection, a multicenter study of interobserver variation.
PubMed 文献 · Surg Endosc · 2023-01-09

视觉评估参数在观察者间差异大,且吻合口漏组与无漏组无显著差异;但定量像素分析显示漏组荧光时间曲线斜率中位数0.08(0.07;0.10)显著低于无漏组0.13(0.10;0.17)(p=0.04)。

要点

  • 外科医生视觉评估ICG荧光成像的观察者间差异大。
  • 视觉评估的TTV、TMV、TWO在吻合口漏组与无漏组无显著差异。
  • 定量像素分析显示漏组荧光时间曲线斜率显著低于无漏组。

核心结论

  • 外科医生视觉评估ICG-FI观察者间差异大,且未能区分吻合口漏患者。
  • 定量像素分析显示吻合口漏组与无漏组荧光时间曲线斜率存在显著差异。

研究设计与样本

  • 多中心研究,纳入接受机器人辅助低位前切除吻合器吻合的患者。
  • 术中由外科医生视觉评估ICG-FI,术后匿名交换视频进行观察者间评估。
  • 使用验证过的像素分析软件对ICG-FI视频记录进行定量血流灌注分析。

主要发现

  • Bland-Altman图显示视觉评估荧光所有参数(TTV、TMV、TWO)的观察者间差异大。
  • 吻合口漏组与无漏组比较,TTV的HR=0.82(CI 0.32; 2.08),TMV的HR=0.62(CI 0.24; 1.59),TWO的HR=1.11(CI 0.40; 3.11),均无显著差异。
  • 定量像素分析中,后续发生漏的患者荧光时间曲线斜率中位数为0.08(0.07;0.10),无漏患者为0.13(0.10;0.17)(p=0.04)。

临床怎么用

  • 视觉评估ICG-FI在判断吻合口灌注时需注意观察者间差异。
  • 定量像素分析可能有助于识别吻合口漏风险较高的患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Securing sufficient blood perfusion to the anastomotic area after low-anterior resection is a crucial factor in preventing anastomotic leakage (AL). Intra-operative indocyanine green fluorescent imaging (ICG-FI) has been suggested as a tool to assess perfusion. However, knowledge of inter-observer variation among surgeons in the interpretation of ICG-FI is sparse. Our primary objective was to evaluate inter-observer variation among surgeons in the interpretation of bowel blood-perfusion assessed visually by ICG-FI. Our secondary objective was to compare the results both from the visual assessment of ICG and from computer-based quantitative analyses of ICG-FI between patients with and without the development of AL. METHOD: A multicenter study, including patients undergoing robot-assisted low anterior resection with stapled anastomosis. ICG-FI was evaluated visually by the surgeon intra-operatively. Postoperatively, recorded videos were anonymized and exchanged between centers for inter-observer evaluation. Time to visibility (TTV), time to maximum visibility (TMV), and time to wash-out (TWO) were visually assessed. In addition, the ICG-FI video-recordings were analyzed using validated pixel analysis software to quantify blood perfusion. RESULTS: Fifty-five patients were included, and five developed clinical AL. Bland-Altman plots (BA plots) demonstrated wide inter-observer variation for visually assessed fluorescence on all parameters (TTV, TMV, and TWO). Comparing leak-group with no-leak group, we found no significant differences for TTV: Hazard Ratio; HR = 0.82 (CI 0.32; 2.08), TMV: HR = 0.62 (CI 0.24; 1.59), or TWO: HR = 1.11 (CI 0.40; 3.11). In the quantitative pixel analysis, a lower slope of the fluorescence time-curve was found in patients with a subsequent leak: median 0.08 (0.07;0.10) compared with non-leak patients: median 0.13 (0.10;0.17) (p = 0.04). CONCLUSION: The surgeon's visual assessment of the ICG-FI demonstrated wide inter-observer variation, there were no differences between patients with and without AL. However, quantitative pixel analysis showed a significant difference between groups. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04766060.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Larsen PO, Nerup N, Andersen J, et al. Anastomotic perfusion assessment with indocyanine green in robot-assisted low-anterior resection, a multicenter study of interobserver variation. Surg Endosc. 2023. PMID: 36624218. doi:10.1007/s00464-022-09819-1