文献速递甲状腺与颈部外科围术期管理与 ERAS

甲状旁腺近红外自发荧光成像的多中心评估

A multicenter evaluation of near-infrared autofluorescence imaging of parathyroid glands in thyroid and parathyroid surgery.
PubMed 文献 · Surgery · 2022-10-28

该前瞻性多中心协作研究在7个学术中心纳入827例甲状腺切除和甲状旁腺切除手术,并通过问卷收集24名术者意见。结果显示近红外自发荧光在识别甲状旁腺、判断腺体正常与异常、排除意外甲状旁腺切除等方面有潜在用途,但多数术者认为其未改善甲状旁腺切除成功率或异位腺体寻找能力。

要点

  • 42%术者认为近红外自发荧光有助于在甲状旁腺显现前识别腺体。
  • 66%术者在甲状腺切除中常规用其排除意外甲状旁腺切除。
  • 87%和78%术者分别认为其未改善甲状旁腺切除成功率或异位腺体寻找能力。

核心结论

  • 该调查研究识别了近红外自发荧光最具潜在用途的领域,可为未来客观试验奠定基础。

研究设计与样本

  • 前瞻性多中心协作研究,在7个学术中心纳入827例甲状腺切除和甲状旁腺切除手术。
  • 向24名参与术者发放问卷以收集专家意见。

主要发现

  • 42%的术者认为近红外自发荧光有助于在甲状旁腺显现前识别甲状旁腺。
  • 67%的术者将近红外自发荧光模式与正常和异常腺体相关联。
  • 38%的术者使用近红外自发荧光而非冰冻切片来确认甲状旁腺组织。
  • 87%和78%的术者分别报告近红外自发荧光未改善甲状旁腺切除后的成功率或寻找异位腺体的能力。
  • 甲状腺切除中66%的术者常规使用近红外自发荧光排除意外甲状旁腺切除,但仅36%和45%的术者分别认为其降低意外甲状旁腺切除率和改善中央颈清扫中保留甲状旁腺的能力。

临床怎么用

  • 近红外自发荧光可用于辅助甲状旁腺识别和排除意外甲状旁腺切除,但不应高估其改善手术成功率或寻找异位腺体的作用。

局限性

  • 本研究为调查研究,主要反映术者主观意见,尚需未来客观试验验证该技术的效用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The usefulness of incorporating near-infrared autofluorescence into the surgical workflow of endocrine surgeons is unclear. Our aim was to develop a prospective registry and gather expert opinion on appropriate use of this technology. METHODS: This was a prospective multicenter collaborative study of patients undergoing thyroidectomy and parathyroidectomy at 7 academic centers. A questionnaire was disseminated among 24 participating surgeons. RESULTS: Overall, 827 thyroidectomy and parathyroidectomy procedures were entered into registry: 42% of surgeons found near-infrared autofluorescence useful in identifying parathyroid glands before they became apparent; 67% correlated near-infrared autofluorescence pattern to normal and abnormal glands; 38% of surgeons used near-infrared autofluorescence, rather than frozen section, to confirm parathyroid tissue; and 87% and 78% of surgeons reported near-infrared autofluorescence did not improve the success rate after parathyroidectomy or the ability to find ectopic glands, respectively. During thyroidectomy, 66% of surgeons routinely used near-infrared autofluorescence to rule out inadvertent parathyroidectomy. However, only 36% and 45% felt near-infrared autofluorescence decreased inadvertent parathyroidectomy rates and improved ability to preserve parathyroid glands during central neck dissections, respectively. CONCLUSION: This survey study identified areas of greatest potential use for near-infrared autofluorescence, which can form the basis of future objective trials to document the usefulness of this technology.

来源:Surgery,查看原文。版权归原作者所有。

引用

  1. Sehnem L, Noureldine SI, Avci S, et al. A multicenter evaluation of near-infrared autofluorescence imaging of parathyroid glands in thyroid and parathyroid surgery. Surgery. 2022. PMID: 36511281. doi:10.1016/j.surg.2022.07.057

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。