文献速递甲状腺与颈部外科

无充气经口腔前庭甲状腺切除术的新型悬吊系统

Novel suspension system for gasless transoral vestibular thyroidectomy.
PubMed 文献 · Surg Endosc · 2022-09-15

该回顾性研究纳入75例接受无充气经口腔前庭入路甲状腺切除术(TOETVA)的患者,采用新型工作空间悬吊系统(含自研拉钩、无菌绷带和麻醉架)。结果显示平均手术时间143.27±34.60分钟,平均清扫淋巴结8.00±5.39枚,无中转开放手术,无严重并发症,结论认为该系统可提供充足稳定的工作空间并避免CO2相关并发症。

要点

  • 新型悬吊系统可为无充气TOETVA提供稳定工作空间,避免CO2相关并发症。
  • 75例均成功完成手术,无中转开放,无严重并发症。
  • 常见暂时性并发症包括RLN麻痹4例、低钙血症9例、颏神经损伤3例。

核心结论

  • 新型工作空间悬吊系统用于无充气TOETVA可提供足够且稳定的工作空间,优化术野清晰度,且无CO2相关并发症。

研究设计与样本

  • 回顾性分析75例连续接受无充气TOETVA并使用新型悬吊系统的患者,悬吊系统包括自研拉钩、无菌绷带和麻醉架。

主要发现

  • 平均手术时间为143.27±34.60分钟,平均清扫淋巴结数为8.00±5.39枚。
  • 无中转开放手术,无严重术后并发症。
  • 术后并发症包括暂时性喉返神经麻痹4例、暂时性甲状旁腺功能减退9例、暂时性颏神经损伤3例。
  • 1例术后皮下积液经抽吸后恢复,1例颏下小穿孔经缝合后恢复良好。
  • 无与自研拉钩相关的特异性并发症证据。

临床怎么用

  • 对于有美容需求且适合经口腔前庭入路甲状腺切除术的患者,可考虑采用该悬吊系统实现无充气操作,以减少CO2相关并发症。

局限性

  • 本研究为单中心回顾性分析,样本量有限,且缺乏对照组,结论需进一步前瞻性研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The transoral endoscopic thyroidectomy vestibular approach (TOETVA) is receiving increased attention, frequently due to growing requirements for cosmetic incisions. Here, we report our initial experience and discuss the safety and efficacy of the innovative surgical working space suspension system for gasless TOETVA. METHODS: We retrospectively analyzed 75 consecutive patients for whom gasless TOETVA with our novel working space suspension system was used. This suspension system included self-developed retractors, a sterile bandage, and an anesthesia stand. We also improved some main surgical instruments in gasless TOETVA. RESULTS: The study included 75 patients who successfully underwent thyroidectomy and central neck dissection via gasless TOETVA. The mean operating time was 143.27 ± 34.60 min. The mean number of retrieved lymph nodes was 8.00 ± 5.39. Conversion to open surgery did not occur, nor did patients exhibit serious postoperative complications. Postoperative complications included 4 cases of transient recurrent laryngeal nerve (RLN) palsy, 9 of transient hypoparathyroidism, and 3 of transient mental nerve injury. One patient with subcutaneous fluid after surgery recovered after aspiration. Another patient with submental minor perforation recovered well after suturing. There was no evidence of specific complications related to self-designed retractors. CONCLUSION: The innovative working space suspension system for gasless TOETVA provided enough and stable working space and optimized the clarity of the surgical field without CO2-related complications.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Jiang J, He G, Chu J, et al. Novel suspension system for gasless transoral vestibular thyroidectomy. Surg Endosc. 2022. PMID: 36109361. doi:10.1007/s00464-022-09528-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。