腹腔镜激光散斑对比成像与吲哚菁绿近红外成像在猪模型术中组织血流灌注中的可行性与比较

Feasibility and comparison of laparoscopic laser speckle contrast imaging to near-infrared display of indocyanine green in intraoperative tissue blood flow/tissue perfusion in preclinical porcine models.
PubMed 文献 · Surg Endosc · 2022-09-16

本研究在六只猪模型上比较了新型腹腔镜激光散斑对比成像(LSCI)与吲哚菁绿(ICG)近红外荧光(NIRF)在术中实时组织血流/灌注可视化中的表现。结果显示LSCI无需染料即可实时(延迟<150 ms,p<0.01)、可重复检测灌注,而ICG在注射后≥5分钟在缺血小肠和部分胃切除术中出现不一致(p<0.0001)。结论认为LSCI联合ICG可提高灌注检测的精确性和准确性。

要点

  • LSCI无需荧光染料注射即可实时、可重复检测组织血流灌注。
  • ICG在注射后≥5分钟于缺血小肠和部分胃切除术中出现灌注分界线不一致。
  • LSCI与ICG联合可提高术中灌注检测的精确性和准确性。

核心结论

  • LSCI联合ICG荧光检测血容量比单独ICG显著提高组织灌注检测的精确性和准确性,且可实时、按需重复进行。

研究设计与样本

  • 在六只猪模型上,由经验丰富的外科医生检查LSCI和ICG在节段性缺血小肠、部分胃切除术和肾门中的应用。
  • 在盲法受试者中(包括不同经验水平的外科医生)确定识别缺血/灌注分界线的精确性和准确性。

主要发现

  • LSCI灌注检测实时(延迟<150 ms:p<0.01),可重复且按需进行,无需荧光团注射。
  • 6名操作外科医生立即在白光、LSCI和ICG模式下精确准确地识别一致的分界线。
  • 21名盲法受试者在ICG注射后≤2分钟所有三种模式显示相似的空间-时间精确性和准确性。
  • 在缺血小肠(p<0.0001)和部分胃切除术(p<0.0001)中,ICG模式在≥5分钟时出现不一致。

临床怎么用

  • 在临床相关场景中,可考虑使用LSCI进行无染料、实时、可重复的组织血流灌注评估。
  • LSCI可与ICG荧光联合使用,以提高术中灌注检测的精确性和准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To determine if laser speckle contrast imaging (LSCI) mitigates variations and subjectivity in the use and interpretation of indocyanine green (ICG) fluorescence in the current visualization paradigm of real-time intraoperative tissue blood flow/perfusion in clinically relevant scenarios. METHODS: De novo laparoscopic imaging form-factor detecting real-time blood flow using LSCI and blood volume by near-infrared fluorescence (NIRF) of ICG was compared to ICG NIRF alone, for dye-less real-time visualization of tissue blood flow/perfusion. Experienced surgeons examined LSCI and ICG in segmentally devascularized intestine, partial gastrectomy, and the renal hilum across six porcine models. Precision and accuracy of identifying demarcating lines of ischemia/perfusion in tissues were determined in blinded subjects with varying levels of surgical experience. RESULTS: Unlike ICG, LSCI perfusion detection was real time (latency < 150 ms: p < 0.01), repeatable and on-demand without fluorophore injection. Operating surgeons (n = 6) precisely and accurately identified concordant demarcating lines in white light, LSCI, and ICG modes immediately. Blinded subjects (n = 21) demonstrated similar spatial-temporal precision and accuracy with all three modes ≤ 2 min after ICG injection, and discordance in ICG mode at ≥ 5 min in devascularized small intestine (p < 0.0001) and in partial gastrectomy (p < 0.0001). CONCLUSIONS: Combining LSCI for near real-time blood flow detection with ICG fluorescence for blood volume detection significantly improves precision and accuracy of perfusion detection in tissue locations over time, in real time, and repeatably on-demand than ICG alone.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Nwaiwu CA, Buharin VE, Mach A, et al. Feasibility and comparison of laparoscopic laser speckle contrast imaging to near-infrared display of indocyanine green in intraoperative tissue blood flow/tissue perfusion in preclinical porcine models. Surg Endosc. 2022. PMID: 36114346. doi:10.1007/s00464-022-09583-2