机器人正中弓状韧带松解术:管理流程与大规模微创系列临床结局
该回顾性队列研究纳入2014至2021年单术者完成的74例机器人正中弓状韧带松解术(MALR),患者平均年龄27.3岁、女性占81.1%。严格遵循管理流程下,机器人MALR安全可行,无中转开腹,1年随访90.3%患者无腹痛。
要点
- 机器人MALR在严格管理流程下安全可行,无中转开腹。
- 术后3个月12%患者持续腹痛,部分经血管成形术缓解。
- 1年随访90.3%患者无腹痛,症状改善持久。
核心结论
- 严格遵循管理流程时,机器人MALR安全可行且患者结局良好。
研究设计与样本
- 回顾性队列研究,纳入2014至2021年单术者完成的74例机器人MALR成人患者。
主要发现
- 平均年龄27.3±7.9岁,女性60/74例(81.1%),餐后腹痛最常见(65/74,87.7%)。
- 平均手术时间52.6±18.1分钟,无中转开腹,平均出血量13.9±8.4 mL。
- 术后3个月12%(9/74)患者持续腹痛并接受额外影像检查。
- 9例中5例舒张期PSV持续升高并转诊血管成形术,其中3例腹痛缓解。
- 1年随访时90.3%(56/62)患者无腹痛。
关键数值与推荐
- MALS诊断标准:腹腔动脉多普勒超声收缩期峰值流速>350 cm/s,结合右上腹超声、食管胃十二指肠镜及CT或MR血管成像排除其他诊断。
临床怎么用
- 机器人MALR可作为严格筛选MALS患者的微创治疗选择。
- 术后持续腹痛者应复查多普勒超声评估PSV,必要时转诊血管成形术。
局限性
- 回顾性单术者研究,样本量有限,结果外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Median arcuate ligament syndrome (MALS) is a rare and debilitating condition that remains difficult to diagnose. Proper patient selection remains key to achieving favorable outcomes for those undergoing MALR. The robotic technique facilitates a minimally invasive MALR approach given the fine precision of the instrumentation and stability of visualization. Here we describe our management algorithm and clinical outcomes for a large series of robotic MALR patients. METHODS: This retrospective cohort study analyzed adult patients who underwent robotic MALR performed by a single surgeon at a tertiary academic hospital from 2014 to 2021. The diagnosis of MALS was made using objective criteria from celiac artery duplex ultrasound with a peak systolic velocity of > 350 cm/s combined with a right upper quadrant abdominal ultrasound, esophagogastroduodenoscopy, and computer tomography or magnetic resonance angiography to exclude other diagnoses. Information on patient demographics, perioperative factors, and patient reported symptoms up to 1-year post-operatively were collected. RESULTS: A total of 74 patients underwent robotic MALR during the study period. The mean age was 27.3 ± 7.9 years and the majority of patients were female (n = 60/74, 81.1%). The most common presenting symptom was post-prandial abdominal pain (n = 65/74, 87.7%). The mean operative time was 52.6 ± 18.1 min. There were no conversions to open surgery and minimal blood loss (mean = 13.9 ± 8.4 mL). At 3-months, 12% (n = 9/74) of patients had persistent abdominal pain and underwent additional imaging. 5 of these 9 patients had persistently elevated DUS expiratory PSV and were referred for angioplasty. 3 of these 5 referred patients had resolution of abdominal pain after angioplasty. At 1-year follow up, 90.3% (n = 56/62) continued to have no abdominal pain. CONCLUSIONS: Through this series, the largest set of minimally invasive (laparoscopic or robotic) MALR procedures published to date, we show that with strict adherence to a management algorithm, the robotic approach to MALR is safe and feasible, with good patient outcomes.
引用
- Gerull WD, Sherrill W, Awad MM, et al. Robotic median arcuate ligament release: management algorithm and clinical outcomes from a large minimally invasive series. Surg Endosc. 2022. PMID: 35999316. doi:10.1007/s00464-022-09545-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。