文献速递围术期管理与 ERAS急腹症与外科感染

降低手术遗留物发生率的策略:射频检测与TeamSTEPPS培训

Risk Reduction Strategy to Decrease Incidence of Retained Surgical Items.
PubMed 文献 · J Am Coll Surg · 2022-08-10

该研究分析了2007至2017年纽约五家大型教学医院报告的997237例手术中手术遗留物(RSI)事件。2012年实施TeamSTEPPS培训并强制使用射频检测后,RSI总发生率从11.66降至5.80/10万手术(OR=0.50,95%CI 0.32-0.78),主要归因于可射频检测物品遗留减少(从5.21降至1.35/10万,OR=0.26,95%CI 0.11-0.60)。

要点

  • 射频检测技术联合TeamSTEPPS培训可显著降低手术遗留物总发生率。
  • 可射频检测物品遗留减少是总发生率下降的主要驱动因素。
  • 非射频检测物品遗留变化无统计学意义。

核心结论

  • 实施射频检测技术和TeamSTEPPS培训后,手术遗留物发生率显著降低。
  • 该降低主要由可射频检测物品遗留减少驱动。
  • 射频检测技术可能值得医院采用以降低手术遗留物频率。

研究设计与样本

  • 回顾性分析2007至2017年纽约五家大型城市教学医院报告至纽约患者事件报告与追踪系统的手术遗留物事件。
  • 共分析997237例手术操作。
  • 2012年对所有围手术期员工提供TeamSTEPPS培训,并强制所有手术使用射频检测。
  • 采用比值比比较干预前后事件发生率。

主要发现

  • 干预后手术遗留物总发生率从11.66降至5.80事件/10万手术(OR=0.50,95%CI 0.32-0.78)。
  • 涉及可射频检测物品的手术遗留物频率从5.21降至1.35事件/10万手术(OR=0.26,95%CI 0.11-0.60)。
  • 涉及非射频检测物品的手术遗留物差异无统计学意义。

临床怎么用

  • 可考虑采用射频检测技术以降低手术遗留物发生率。
  • 仅靠TeamSTEPPS培训可能不足以减少手术遗留物。

局限性

  • 研究为回顾性分析,仅基于纽约五家教学医院报告的数据。
  • 原文未明确报告非射频检测物品遗留的具体数值及统计检验细节。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Retained surgical items (RSIs) are rare but serious events associated with significant morbidity and costs. We assessed the effectiveness of radiofrequency (RF) detection technology and Team Strategies and Tools to Enhance Performance and Patient Safety (TeamSTEPPS) in reducing the incidence of RSIs. STUDY DESIGN: All RSIs reported to the New York Patient Occurrence Reporting and Tracking System at five large urban teaching hospitals from 2007 to 2017 were analyzed. In 2012, TeamSTEPPS training was provided to all perioperative staff at each site, and use of RF detection became required in all procedures. The incidence of events before and after the interventions were compared using odds ratios. RESULTS: A total of 997,237 operative procedures were analyzed. After the interventions, the incidence of RSIs decreased from 11.66 to 5.80 events per 100,000 operations (odds ratio [OR] [95% CI] = 0.50 [0.32 to 0.78]). The frequency of RSIs involving RF-detectable items decreased from 5.21 to 1.35 events per 100,000 operations (OR [95% CI] = 0.26 [0.11 to 0.60]). The difference in RSIs involving non-RF-detectable surgical items was not statistically significant. CONCLUSIONS: The incidence of RSIs was significantly lower during the time period after implementing RF detection technology and after TeamSTEPPS training, primarily driven by a decrease in retained RF-detectable items. RF detection technology may be worth pursuing for hospitals looking to decrease RSI frequency. The benefit of TeamSTEPPS training alone may not result in a reduction of RSIs.

来源:J Am Coll Surg,查看原文。版权归原作者所有。

引用

  1. Kaplan HJ, Spiera ZC, Feldman DL, et al. Risk Reduction Strategy to Decrease Incidence of Retained Surgical Items. J Am Coll Surg. 2022. PMID: 35972170. doi:10.1097/XCS.0000000000000264

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。