文献速递疝与腹壁外科围术期管理与 ERAS

全州质量改进协作组中小型腹壁疝修补方式差异

Variation in approach for small (< 2 cm) ventral hernias across a statewide quality improvement collaborative.
PubMed 文献 · Surg Endosc · 2022-07-19

基于密歇根外科质量协作组疝登记处的回顾性队列研究,纳入2020年1月1日至2021年7月8日期间570例小于2cm腹壁疝修补患者,56.1%使用补片,多数为开放手术。调整患者和疝特征后,ASA III级、当前吸烟、较大疝宽度及腹腔镜或机器人入路与补片使用相关,而COPD与较少补片使用相关。

要点

  • 小于2cm腹壁疝修补中56.1%使用补片,76.5%为开放手术。
  • ASA III级、吸烟、较大疝宽度及腹腔镜/机器人入路与补片使用独立相关。
  • 补片使用可能由并发症高危因素驱动,而非证据表明该人群补片更优。

核心结论

  • 小疝补片使用仍存争议,补片患者可能为并发症更高危人群,决策或由患者因素驱动而非证据优势。

研究设计与样本

  • 回顾性队列研究,纳入密歇根外科质量协作组疝登记处2020年1月1日至2021年7月8日570例小于2cm腹壁疝修补患者。

主要发现

  • 570例中56.1%(n=320)放置补片,开放入路占76.5%(n=437)。
  • 补片组年龄51.8 vs 48.6岁(p<0.01),BMI 31.7 vs 30.0(p<0.01),ASA III级35.9% vs 24.4%(p<0.01),糖尿病15.9% vs 10.0%(p=0.04),高血压44.7% vs 30.4%(p<0.01),疝宽度1.2 cm vs 1.0 cm(p<0.0001)。
  • 调整后ASA III级aOR 3.41(95%CI 1.31-8.89)、当前吸烟aOR 1.81(95%CI 1.04-3.18)、较大疝宽度aOR 5.68(95%CI 2.97-10.85)、腹腔镜aOR 12.9(95%CI 5.02-32.96)、机器人aOR 24.3(95%CI 6.96-84.96)与补片使用相关;COPD aOR 0.36(95%CI 0.07-0.96)与较少补片使用相关。

临床怎么用

  • 对小疝修补决策应评估患者并发症风险与复发风险,而非默认补片更优。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Operative technique for hernias < 2 cm is highly controversial. Limited data exist about this practice at a population level. Within this context we sought to describe practice patterns and use of mesh among patients undergoing repair of small hernias within the setting of a statewide quality improvement collaborative. METHODS: Retrospective cohort study of patients undergoing hernia repair in the Michigan Surgical Quality Collaborative Hernia Registry was conducted. Patients who underwent repair of a hernia < 2 cm from January 1, 2020 to July 8, 2021 were included. Descriptive statistics were performed to describe cohort characteristics and compare patients who did and did not receive mesh. Logistic regression was performed to estimate the odds of receiving mesh after accounting for patient and hernia characteristics. RESULTS: Among 570 patients, 56.1% (n = 320) had mesh placed. Most repairs were conducted via open approach (n = 437, 76.5%). Patients who received mesh were older (51.8 vs 48.6, p < 0.01), had higher BMI (31.7 vs 30.0, p < 0.01), were more often ASA Class III (35.9% vs 24.4%, p < 0.01), more often had diabetes (15.9% vs 10.0%, 0.04) and hypertension (44.7% vs 30.4%, p < 0.01), and had higher hernia width (1.2 cm vs 1.0 cm, p < 0.0001). After adjustment, ASA Class III (aOR 3.41, 95% CI 1.31-8.89), current smoking status (aOR 1.81, 95% CI 1.04-3.18), higher mean hernia width (aOR 5.68, 95% CI 2.97-10.85), and laparoscopic (aOR 12.9, 95% CI 5.02-32.96) or robotic (aOR 24.3, 95% CI 6.96-84.96) were associated with mesh use, while COPD (aOR 0.36, 95% CI 0.07-0.96) was associated with less mesh use. CONCLUSIONS: Use of mesh for small hernias remains controversial. We found that patients who had mesh placed at the time of surgery were potentially patients at higher risk for complications. The decision to use mesh may be driven by patient-related factors that predispose to complications and operative recurrence rather than evidence indicating that it is superior in this population.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Ehlers AP, Howard R, Delaney LD, et al. Variation in approach for small (< 2 cm) ventral hernias across a statewide quality improvement collaborative. Surg Endosc. 2022. PMID: 35854123. doi:10.1007/s00464-021-08957-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。