文献速递胃肠外科围术期管理与 ERAS疝与腹壁外科

带刀与无刀锥形穿刺器在猪模型中所致筋膜缺损大小无差异

Bladed and bladeless conical trocars do not differ in terms of caused fascial defect size in a Porcine Model.
PubMed 文献 · Surg Endosc · 2022-07-18

该研究在5头安乐死雌性猪上交替置入5种12 mm锥形穿刺器(3种无刀、2种带刀),测腹壁筋膜缺损面积。带刀与无刀穿刺器所致缺损大小无显著差异(56.6 vs 59.5 mm²,p=0.7),提示穿刺孔疝发生可能 largely 与穿刺器设计无关。

要点

  • 带刀与无刀12 mm锥形穿刺器所致筋膜缺损面积无显著差异。
  • 总体平均筋膜缺损面积为58.3 mm²(SD 20.2)。
  • 穿刺孔疝发生可能 largely 不取决于穿刺器设计。

核心结论

  • 在猪模型中,带刀与无刀锥形12 mm穿刺器所致筋膜缺损大小无显著差异。
  • 穿刺孔疝的发生可能 largely 与穿刺器设计无关。

研究设计与样本

  • 研究为猪模型实验,共5头安乐死雌性猪,平均体重37.85 kg(SD 1.68),年龄90±5天。
  • 每侧乳腺嵴外侧4 cm交替置入5种不同锥形12 mm穿刺器(3种无刀、2种带刀),由一名外科医生在12 mmHg气腹下用Verres针穿刺后置入。
  • 穿刺器留置60 min后移除,拍照并用GSA Image Analyser(v3.9.6)测量腹壁缺损大小。

主要发现

  • 总体平均筋膜缺损大小为58.3 mm²(SD 20.2)。
  • 带刀穿刺器所致缺损为56.6 mm²(SD 20),无刀穿刺器为59.5 mm²(SD 20.6),组间比较p=0.7。
  • 无统计学意义下,无刀穿刺器Kii Fios™ First entry(APPLIEDMEDICAL©)所致缺损最大(69.3 mm²),VersaOne™(COVIDIEN©)所致缺损最小(54.1 mm²)。

临床怎么用

  • 选择带刀或无刀锥形12 mm穿刺器时,不需以筋膜缺损大小作为主要考量。
  • 穿刺孔疝的预防可能应关注其他因素而非穿刺器设计。

局限性

  • 研究为猪模型,样本量小(5头猪),结果外推至人体需谨慎。
  • 原文未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Trocar insertion during laparoscopy may lead to complications such as bleeding, bowel puncture and fascial defects with subsequent trocar site hernias. It is under discussion whether there is a difference in the extent of the trauma and thus in the size of the fascia defect between blunt and sharp trocars. But the level of evidence is low. Hence, we performed a Porcine Model. METHODS: A total of five euthanized female pigs were operated on. The average weight of the animals was 37.85 (Standard deviation SD 1.68) kg. All pigs were aged 90 ± 5 days. In alternating order five different conical 12-mm trocars (3 × bladeless, 2 × bladed) on each side 4 cm lateral of the mammary ridge were placed. One surgeon performed the insertions after conducting a pneumoperitoneum with 12 mmHg using a Verres' needle. The trocars were removed after 60 min. Subsequently, photo imaging took place. Using the GSA Image Analyser (v3.9.6) the respective abdominal wall defect size was measured. RESULTS: The mean fascial defect size was 58.3 (SD 20.2) mm2. Bladed and bladeless trocars did not significant differ in terms of caused fascial defect size [bladed, 56.6 (SD 20) mm2 vs. bladeless, 59.5 (SD 20.6) mm2, p = 0.7]. Without significance the insertion of bladeless trocars led to the largest (Kii Fios™ First entry, APPLIEDMEDICAL©, 69.3 mm2) and smallest defect size (VersaOne™ (COVIDIEN©, 54.1 mm2). CONCLUSION: Bladed and bladeless conical 12-mm trocars do not differ in terms of caused fascial defect size in the Porcine Model at hand. The occurrence of a trocar site hernia might be largely independent from trocar design.

来源:Surg Endosc,查看原文。版权归原作者所有。