文献速递胃肠外科围术期管理与 ERAS

机器人辅助增强现实系统在妇科腹腔镜手术中识别靶向淋巴结的初步研究

Robotically assisted augmented reality system for identification of targeted lymph nodes in laparoscopic gynecological surgery: a first step toward the identification of sentinel node : Augmented reality in gynecological surgery.
PubMed 文献 · Surg Endosc · 2022-07-13

该研究旨在验证腹腔镜图像与术前CT扫描多模态时间融合用于微创盆腔淋巴结清扫中实时体内靶向淋巴结检测的可行性。在两只猪模型上比较有无增强现实辅助下识别人工靶向淋巴结和解剖标志,结果显示CT叠加准确率>90%,溢出率<6%,增强现实评分显著高于直接视野,对经验丰富和受训外科医生均有帮助。

要点

  • 增强现实辅助系统可实时融合腹腔镜与术前CT图像,识别靶向淋巴结及周围解剖结构。
  • CT叠加准确率>90%,溢出率<6%,增强现实评分显著高于直接视野。
  • 该系统对经验丰富和受训外科医生均有帮助,是迈向临床研究的第一步。

核心结论

  • 该计算机辅助系统可靠、安全且准确,为靶向淋巴结识别提供了新方法,是迈向临床研究的第一步。

研究设计与样本

  • 实验模型研究,先通过测量确定最准确的追踪系统(UR5-Cobot对比NDI Polaris),随后在两只猪上进行干预实验。

主要发现

  • 开发并测试了基于增强现实的机器人辅助系统,可在盆腔淋巴结清扫中实时检测靶向淋巴结及周围解剖结构。
  • CT叠加准确率>90%,溢出率<6%。
  • 与直接视野相比,增强现实对所有目标结构的评分显著更高,且对经验丰富和受训外科医生均有帮助。

关键数值与推荐

  • CT叠加准确率>90%,溢出率<6%。
  • 增强现实与直接视野比较,所有目标结构评分在增强现实组显著更高。

临床怎么用

  • 该系统有望在微创盆腔淋巴结清扫中辅助识别靶向淋巴结及输尿管、血管等解剖结构,提高手术安全性,但尚需临床研究验证。

局限性

  • 研究仅在两只猪的实验模型上进行,样本量小,尚未在临床患者中验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To prove feasibility of multimodal and temporal fusion of laparoscopic images with preoperative computed tomography scans for a real-time in vivo-targeted lymph node (TLN) detection during minimally invasive pelvic lymphadenectomy and to validate and enable such guidance for safe and accurate sentinel lymph node dissection, including anatomical landmarks in an experimental model. METHODS: A measurement campaign determined the most accurate tracking system (UR5-Cobot versus NDI Polaris). The subsequent interventions on two pigs consisted of an identification of artificial TLN and anatomical landmarks without and with augmented reality (AR) assistance. The AR overlay on target structures was quantitatively evaluated. The clinical relevance of our system was assessed via a questionnaire completed by experienced and trainee surgeons. RESULTS: An AR-based robotic assistance system that performed real-time multimodal and temporal fusion of laparoscopic images with preoperative medical images was developed and tested. It enabled the detection of TLN and their surrounding anatomical structures during pelvic lymphadenectomy. Accuracy of the CT overlay was > 90%, with overflow rates < 6%. When comparing AR to direct vision, we found that scores were significatively higher in AR for all target structures. AR aided both experienced surgeons and trainees, whether it was for TLN, ureter, or vessel identification. CONCLUSION: This computer-assisted system was reliable, safe, and accurate, and the present achievements represent a first step toward a clinical study.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Lecointre L, Verde J, Goffin L, et al. Robotically assisted augmented reality system for identification of targeted lymph nodes in laparoscopic gynecological surgery: a first step toward the identification of sentinel node : Augmented reality in gynecological surgery. Surg Endosc. 2022. PMID: 35831676. doi:10.1007/s00464-022-09409-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。