文献速递甲状腺与颈部外科围术期管理与 ERAS

术中神经监测对甲状腺切除术中喉返神经损伤风险的影响:双稳健方法

Effect of Intraoperative Neuromonitoring on the Risks of Recurrent Laryngeal Nerve Injury During Thyroidectomy: A Doubly Robust Approach.
PubMed 文献 · Ann Surg · 2022-07-15

OBJECTIVE: To evaluate the relationship between the use intraoperative neuromonitoring (IONM) during thyroidectomy and the risk of recurrent laryngeal nerve (RLN) injury. BACKGROUND: The role of IONM in reducing RLN injury during thyroidectomy remains controversial.…

要点

  • IONM使用与喉返神经损伤风险显著降低相关(RR 0.77)。
  • IONM使用与术后住院时间缩短约2.5小时相关。
  • IONM使用与手术时间延长约15.41分钟相关。

核心结论

  • 在NSQIP多中心甲状腺切除术患者中,使用IONM与喉返神经损伤风险降低相关。

主要发现

  • 敏感性分析显示估计结果对混杂因素基本稳健。

临床怎么用

  • 甲状腺切除术中可考虑使用IONM以降低喉返神经损伤风险,但需权衡手术时间延长。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate the relationship between the use intraoperative neuromonitoring (IONM) during thyroidectomy and the risk of recurrent laryngeal nerve (RLN) injury. BACKGROUND: The role of IONM in reducing RLN injury during thyroidectomy remains controversial. Several studies on this topic apply conventional multivariable regression to adjust for confounding. However, estimates from this method may be biased due to model misspecification, especially with a rare outcome such as RLN injury. METHODS: We used a pooled dataset created by linking the 2016-2019 National Surgical Quality Improvement Project General Participant User File with the corresponding Targeted-Thyroidectomy file. The primary outcome was RLN injury rates, and the secondary outcomes were operating time and postoperative length of stay. A doubly robust (DR) estimator, in the form of an inverse-probability-weighted regression adjustment model, was used to estimate the effect of the use of IONM on the risk of RLN injury. Sensitivity analyses was performed. RESULTS: Twenty-four thousand three hundred seventy patients were evaluated, out of which 15,836 (70%) patients had IONM during thyroidectomy, and RLN injury occurred in 1498 (6.2%) cases. Rates of RLN injury increase with increasing age and BMI and are higher in patients with a cancer diagnosis, previous neck operation, total thyroidectomy, and node dissection. Doubly robust model suggests that the use of IONM was associated with a significant reduction in overall rate of RLN injury [risk ratio 0.77, confidence interval (CI), 0.68-0.87, P <0.001], and postoperative length of stay [-2.5 hours (CI, -4.18 to -0.81 h), P =0.004]. However, IONM use was associated with an increase in operating time [15.41 minutes (CI, 13.29-17.54 minutes), P <0.0001]. Sensitivity analyses revealed that our estimates are largely robust to confounding. CONCLUSION: In a balanced cohort of patients undergoing thyroidectomy from multiple sites and surgeons participating in National Surgical Quality Improvement Project, the use of IONM during thyroidectomy was associated with reduction in RLN injury.

来源:Ann Surg,查看原文。版权归原作者所有。

引用

  1. Memeh K, Vaghaiwalla T, Keutgen X, et al. Effect of Intraoperative Neuromonitoring on the Risks of Recurrent Laryngeal Nerve Injury During Thyroidectomy: A Doubly Robust Approach. Ann Surg. 2022. PMID: 35837957. doi:10.1097/SLA.0000000000005588

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。