非机器人中心采用eTEP-RS修补切口疝:腹腔镜能否实现持久微创腹壁缺损修补?
平均手术时间211分钟(145-295),缺损平均宽度6.8 cm、面积42.5 cm²,补片平均498 cm²(270-625)。平均随访16个月(2-30)无复发或重大并发症,结论认为eTEP-RS在选定病例中是开放修补的安全替代,可置入大补片并符合当前推荐。
要点
- 切口疝可累及多达25%的剖腹手术,修补仍具挑战。
- 非机器人中心行腹腔镜eTEP-RS,34例随访16个月无复发或重大并发症。
- 需熟悉腹壁详细解剖并遵循腹腔镜eTEP-RS操作规则以改善人机工效。
核心结论
- eTEP-RS在选定病例中是开放腹壁疝修补的安全替代,即使在非机器人中心也可按当前推荐置入大补片。
主要发现
- 平均手术时间211分钟(145-295)。
- 缺损平均宽度6.8 cm,缺损面积42.5 cm²。
- 补片平均大小498 cm²(270-625)。
- 平均随访16个月(2-30),无复发或重大并发症。
关键数值与推荐
- 切口疝可累及多达25%的剖腹手术。
- 入选疝环范围为4-10 cm。
临床怎么用
- 在非机器人中心,掌握腹壁详细解剖并遵循腹腔镜eTEP-RS操作规则可改善人机工效,安全完成大补片置入。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Incisional hernias can complicate up to 25% of laparotomies, and successful repair remains a significant clinical challenge for surgeons. Recently, the surgical technique of ventral hernia repair (eTEP-RS) has been introduced. The method was presented relatively recently and continues to evolve. The use of a robotic platform in eTEP-RS resulted in a significant improvement in ergonomics. Therefore, the questions arise as to whether the laparoscopic technique might still be feasible for such long procedures. The objective of this study is to present our early results in the treatment of patients with incisional ventral hernias using eTEP-RS and to discuss key technical aspects. PATIENTS AND METHODS: A prospective case-controlled study was conducted for all incisional ventral hernia patients (hernia orifice between 4 and 10 cm) who underwent eTEP-RS between March 2019 and December 2021. Demographic data were recorded; and perioperative and postoperative results were analyzed. RESULTS: We performed 34 eTEP-RS procedures. The mean duration of the surgery was 211 min (145-295). The mean width of the defect was 6.8 cm and the defect area was 42.5 cm2. The mean mesh size was 498 cm2 (270-625). After an average follow-up of 16 months (2-30), there was no recurrence or major complication. CONCLUSIONS: The eTEP-RS is a safe alternative to open ventral hernia repair in selected cases and allows for the placement of a large piece of mesh in accordance with current recommendations, even in non-robotic centers. Excellent knowledge of the detailed anatomy of the abdominal wall is essential for safe and effective hernia repair. Compliance with certain rules of the laparoscopic eTEP-RS facilitates improved ergonomics for this procedure even in non-robotic centers.
引用
- Mitura K, Romańczuk M, Kisielewski K, et al. eTEP-RS for incisional hernias in a non-robotic center. Is laparoscopy enough to perform a durable MIS repair of the abdominal wall defect? Surg Endosc. 2022. PMID: 35680666. doi:10.1007/s00464-022-09365-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。