结直肠手术中吲哚菁绿荧光评估的最佳时机与距离:SERGREEN定量研究
这项前瞻性观察研究在择期腹腔镜结直肠手术患者中,用SERGREEN程序定量测量吲哚菁绿(ICG)荧光强度。最佳分析时机在20例患者(左右半结肠各10例)中测试,最佳距离在10例患者中测试。结果显示左右半结肠ICG荧光强度均在给药后1.5至3.5分钟最佳,最佳测量距离为5厘米。
要点
- 左右半结肠ICG荧光评估最佳时机均为给药后1.5至3.5分钟
- 相机距组织5厘米时测量置信区间最窄,为最佳距离
- 荧光饱和度与相机和组织间距离呈反比
核心结论
- 结肠ICG荧光评估最佳时机为给药后1.5至3.5分钟,左右半结肠一致。
- 最佳测量距离为距组织5厘米。
研究设计与样本
- 前瞻性观察研究,纳入择期腹腔镜结直肠手术患者。
- 最佳时机在20例患者(右半结肠10例、左半结肠10例)中测试,最佳距离在10例患者中测试。
主要发现
- 荧光强度在给药后1.5分钟达峰,右半结肠为112.49,左半结肠为93.95。
- 荧光强度维持稳定至3.5分钟,右半结肠为98.49,左半结肠为83.35,之后逐渐下降。
- ICG饱和度与相机至组织距离呈反比,5厘米处置信区间最窄(CI 86.66-87.53)。
关键数值与推荐
- 最佳分析时机:给药后1.5至3.5分钟,适用于右半结肠和左半结肠。
- 最佳测量距离:5厘米。
临床怎么用
- 结直肠手术中可在ICG给药后1.5至3.5分钟、距组织5厘米处进行荧光定量评估。
- 该参数有助于建立正常与病理状态下荧光比较的参考标准。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Suture dehiscence is one of the most feared postoperative complications. Correct intestinal vascularization is essential for its prevention. Indocyanine green (ICG) is one of the methods used to assess vascularization, but this assessment is usually subjective. Our group designed the SERGREEN program to obtain an objective measurement of the degree of vascularization. We do not know how long after ICG administration the fluorescence of the tissues should be evaluated, or how far away the measurement should be performed. The aim of this study is to establish the optimal moment and distance for analyzing the fluorescence saturation of ICG. METHODS: Prospective observational study in patients undergoing elective laparoscopic colorectal surgery. The optimal time for ICG analysis was tested in a sample of 20 patients (10 right colon and 10 left colon), and the optimal distance in a sample of ten patients. ICG was administered intravenously, and colon vascularization was quantified using SERGREEN; RGB (Red, Green, Blue) encoding was used. The intensity curve of the ICG was analyzed for ten minutes after its administration. Distances of 1, 3, and 5 cm were tested. RESULTS: The intensity of fluorescence increased until 1.5 min after ICG administration (reaching figures of 112.49 in the right colon and 93.95 in the left). It then remained fairly stable until 3.5 min (98.49 in the right and 83.35 in the left), at which point it began to decrease gradually. ICG saturation was inversely proportional to the distance between the camera and the tissue. The best distance was 5 cm, where the confidence interval was narrower [CI 86.66-87.53]. CONCLUSION: The optimal time for determining ICG in the colon is between 1.5 and 3.5 min, in both right and left colon. The optimal distance is 5 cm. This information will help to establish parameters of comparison in normal and pathological situations.
引用
- Serra-Aracil X, Lucas-Guerrero V, Garcia-Nalda A, et al. When should indocyanine green be assessed in colorectal surgery, and at what distance from the tissue? Quantitative measurement using the SERGREEN program. Surg Endosc. 2022. PMID: 35668312. doi:10.1007/s00464-022-09343-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。