改良Larssen液固定尸体模型用于经口腔前庭入路甲状腺内镜手术培训的可行性研究
本研究使用15具改良Larssen液(MLS)固定的人体尸体,连续两年开展为期一天的经口腔前庭入路甲状腺内镜手术(TOETVA)尸体培训班,通过问卷评估课程结构、尸体感官特性及培训效果并做成本评估。
要点
- MLS固定尸体可保持实施TOETVA手术步骤所需的感官特性。
- MLS固定尸体可存储4.53年并重复使用6.27次,降低培训成本。
- MLS固定尸体TOETVA培训班成本约为其他TOETVA培训班的一半。
核心结论
- MLS固定人体尸体模型用于TOETVA培训具有可行性,能保持手术步骤实施所需的感官特性并降低培训成本。
研究设计与样本
- 研究使用15具MLS固定人体尸体,连续两年开展为期一天的TOETVA尸体培训班,对全部培训者进行培训后口头和在线问卷调查并做成本评估。
主要发现
- 89.8%的全部参与者、94.4%的动手操作学员和83.3%的观察学员正面认可TOETVA全部步骤的实施。
- 关于人体尸体和教学质量,13.2名(94.5%)培训者和33.3名(92.5%)学员认为10.8±0.8具(范围10-12)人体尸体对TOETVA全部步骤是「实用的」。
- 尸体被存储4.53年并重复使用6.27次,用于内镜培训班和研究。
- 使用MLS固定人体尸体可重复使用的TOETVA培训班成本是其他已开展TOETVA培训班的一半。
临床怎么用
- MLS固定人体尸体可作为TOETVA培训的可行模型,适合普通外科和耳鼻喉科医生参加短期尸体培训班。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Training formats for transoral endoscopic thyroidectomy vestibular approach (TOETVA) are limited. Our aim was to create and investigate a TOETVA training model for general and ENT surgeons. METHODS: A total of 15 modified Larssen solution (MLS) human cadavers were used in the study. A day duration TOETVA human cadaver workshops were offered in two years consecutive. Post-training verbal and online questionnaires were applied to all trainers to evaluate course structure and program, organoleptic characteristics of MLS-fixed human cadavers, and TOETVA training effectiveness. Cost assessment is included in the study. RESULTS: Ninety-eight participants, i.e., 14 trainers and 84 hands-on (HO) and observer (OB) trainees, attended the workshops, completed the tasks assigned, and fulfilled the questionnaires. Implementation of all steps of TOETVA was approved positively by 89.8% of all participants, 94.4% of HO, and 83.3% of OB trainees. Regarding human cadaver and teaching quality, 10.8 ± 0.8 (10-12) human cadavers were "practical" by 13.2 (94.5%) of the trainers, and by 33.3 (92.5%) of the trainees for all steps of TOETVA. The cadavers were stored for 4.53 years and used 6.27 times repeatedly for endoscopic workshops and research studies. TOETVA workshop cost with repeatable use of MLS-fixed human cadaver is half of other performed TOETVA workshops. CONCLUSIONS: A TOETVA human cadaver workshop model has not been reported yet. Our findings suggest the feasibility of MLS-fixed human cadaver model for training of TOETVA, preserve the organoleptic properties necessary for the implementation of surgical steps, and reduce the cost.
引用
- Celik S, Bilge O, Ozdemir M, et al. Modified Larssen solution (MLS)-fixed cadaver model for transoral endoscopic thyroidectomy vestibular approach (TOETVA) education: a feasibility study. Surg Endosc. 2022. PMID: 35471255. doi:10.1007/s00464-022-09224-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。