文献速递胃肠外科围术期管理与 ERAS

右半结肠切除扩大D3系膜切除中肠系膜上动脉神经丛损伤范围的三维多模态分析

Reconstructing topography and extent of injury to the superior mesenteric artery plexus in right colectomy with extended D3 mesenterectomy: a composite multimodal 3-dimensional analysis.
PubMed 文献 · Surg Endosc · 2022-04-05

本研究通过解剖、尸体组织学和手术标本组织学三组,描述肠系膜上动脉神经丛(SMAP)的显微解剖及右半结肠癌扩大D3系膜切除后的损伤程度。结果显示SMAP环绕SMA并走行于血管周围鞘内,淋巴结位于鞘外,组织学上横断损伤占神经面积的48%和神经数量的59%。

要点

  • SMAP呈网状环绕SMA并分支于血管周围鞘内,淋巴结位于鞘外。
  • 组织学横断损伤占神经面积48%、神经数量59%。
  • 神经纤维斜行角度35°–55°,提示神经丛切除可能造成更大损伤。

核心结论

  • SMAP环绕SMA并在血管周围鞘内分支,肠道淋巴结和血管位于鞘外。
  • 组织学切片上SMAP横断损伤为神经面积的48%和神经数量的59%。
  • SMAP神经35°–55°的斜行角度可能提示神经丛切除时损伤更大。

研究设计与样本

  • 研究分三组:解剖解剖组5例(3女,80-93岁)、死后组织学组7例(5女,71-86岁)、手术标本组织学组9例(5女,55-69岁)。
  • 比较组II与组III的神经计数和面积,以及组I与组II的血管周围鞘厚度。
  • 通过3D组织学、纳米CT扫描和3D打印生成三维模型。

主要发现

  • 组II神经计数53 ± 12.42(38-68),面积1.84 ± 0.50 mm²(1.16-2.29)。
  • 组III神经计数31.6 ± 6.74(23-43),面积0.889 ± 0.45 mm²(0.479-1.668)。
  • 结肠中动脉起源水平SMAP横断损伤为神经数量的59%和神经面积的48%。
  • 血管周围鞘厚度中位数向尾侧递减:解剖解剖组从2.05降至1.04 mm,死后组织学组从2.65降至1.17 mm。
  • 3D组织学模型显示神经纤维仅位于血管周围鞘内,淋巴结仅见于鞘外;纳米CT模型显示神经纤维斜行角度35°–55°。

关键数值与推荐

  • 组II神经计数53 ± 12.42(38-68),面积1.84 ± 0.50 mm²(1.16-2.29)。
  • 组III神经计数31.6 ± 6.74(23-43),面积0.889 ± 0.45 mm²(0.479-1.668)。
  • SMAP横断损伤为神经数量的59%和神经面积的48%。
  • 血管周围鞘厚度中位数:解剖解剖组2.05至1.04 mm,死后组织学组2.65至1.17 mm。
  • 神经纤维斜行角度35°–55°。

临床怎么用

  • 右半结肠癌扩大D3系膜切除时,应识别并保护血管周围鞘内的SMAP神经纤维。
  • 淋巴结位于血管周围鞘外,清扫时应注意避免过度切除鞘内神经组织。
  • 术后顽固性腹泻可能与SMAP损伤相关,需关注神经丛保护。

局限性

  • 样本量小,共21例标本。
  • 组间年龄和性别分布不完全匹配。
  • 组织学损伤评估仅基于横断切片。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Superior mesenteric artery plexus (SMAP) injury is reported to cause postoperative intractable diarrhea after pancreatic/colonic surgery with extended lymphadenectomy. This study aims to describe the SMAP microanatomy and extent of injury after right colectomy with extended D3 mesenterectomy for cancer. METHODS: Three groups (I) anatomical dissection, (II) postmortem histology, and (III) surgical specimen histology were included. Nerve count and area were compared between groups II and III and paravascular sheath thickness between groups I and II. 3D models were generated through 3D histology, nanoCT scanning, and finally through 3D printing. RESULTS: A total of 21 specimens were included as follows: Group (I): 5 (3 females, 80-93 years), the SMAP is a complex mesh surrounding the superior mesenteric artery (SMA), branching out, following peripheral arteries and intertwining between them, (II): 7 (5 females, 71-86 years), nerve count: 53 ± 12.42 (38-68), and area: 1.84 ± 0.50 mm2 (1.16-2.29), and (III): 9 (5 females, 55-69 years), nerve count: 31.6 ± 6.74 (range 23-43), and area: 0.889 ± 0.45 mm2 (range 0.479-1.668). SMAP transection injury is 59% of nerve count and 48% of nerve area at middle colic artery origin level. The median values of paravascular sheath thickness decreased caudally from 2.05 to 1.04 mm (anatomical dissection) and from 2.65 to 1.17 mm (postmortem histology). 3D histology models present nerve fibers exclusively within the paravascular sheath, and lymph nodes were observed only outside. NanoCT-derived models reveal oblique nerve fiber trajectories with inclinations between 35° and 55°. Two 3D-printed models of the SMAP were also achieved in a 1:2 scale. CONCLUSION: SMAP surrounds the SMA and branches within the paravascular sheath, while bowel lymph nodes and vessels lie outside. Extent of SMAP injury on histological slides (transection only) was 48% nerve area and 59% nerve count. The 35°-55° inclination range of SMAP nerves possibly imply an even larger injury when plexus excision is performed (lymphadenectomy). Reasons for later improvement of bowel function in these patients can lie in the interarterial nerve fibers between SMA branches.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Luzon JA, Thorsen Y, Nogueira LP, et al. Reconstructing topography and extent of injury to the superior mesenteric artery plexus in right colectomy with extended D3 mesenterectomy: a composite multimodal 3-dimensional analysis. Surg Endosc. 2022. PMID: 35380284. doi:10.1007/s00464-022-09200-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。