文献速递疝与腹壁外科

机器人辅助腹股沟疝修补术研究多数存在报告偏倚:一项系统综述

Spin is present in the majority of articles evaluating robot-assisted groin hernia repair: a systematic review.
PubMed 文献 · Surg Endosc · 2022-01-13

该系统综述纳入35项评估机器人辅助腹股沟疝修补术的研究,发现57%存在报告偏倚(spin),其中95%的偏倚出现在摘要、80%出现在结论。研究规模与偏倚无关联(p>0.05),但支持机器人手术的研究偏倚率更高(p<0.001),且接受Intuitive Surgical资助或拨款的研究偏倚率更高(p<0.05)。

要点

  • 57%的机器人辅助腹股沟疝修补术研究存在报告偏倚(spin)。
  • 存在偏倚的研究中,95%在摘要、80%在结论部分出现偏倚。
  • 接受机器人公司资助或拨款的研究偏倚率更高(p<0.05)。

核心结论

  • 机器人辅助腹股沟疝修补术相关文献中报告偏倚常见,且在接受机器人公司资助或拨款的研究中偏倚率更高,提示读者阅读类似文献时应谨慎。

研究设计与样本

  • 系统综述,遵循PRISMA指南,方案在PROSPERO注册,检索PubMed、EMBASE和Cochrane Central数据库,最终纳入35项研究。

主要发现

  • 35项纳入研究中,57%存在报告偏倚(spin)。
  • 存在偏倚的研究中,95%在摘要中出现偏倚,80%在文章结论中出现偏倚。
  • 研究规模与报告偏倚无关联(p>0.05)。
  • 对机器人辅助疝修补术持正面观点的研究,其报告偏倚出现率高于持反对或中立观点的研究(p<0.001)。
  • 接受Intuitive Surgical资助或拨款的研究,其报告偏倚出现率高于未接受者(p<0.05)。

临床怎么用

  • 阅读机器人辅助腹股沟疝修补术相关文献时,应警惕摘要和结论中可能存在的报告偏倚,尤其是接受机器人公司资助的研究。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The number of scientific articles published each year is increasing, resulting in greater competition to get work published. Spin is defined as specific reporting strategies used to distort the readers' interpretation of results so that they are viewed more favorable. However, prevalence of spin in studies comparing robot-assisted groin hernia repair with traditional methods is unknown. OBJECTIVES/AIM: To determine the frequency and extent of spin in studies assessing robot-assisted groin hernia repair. METHODS: This systematic review was reported according to PRISMA guidelines, and a protocol was registered at PROSPERO before data extraction. Database search included PubMed, EMBASE, and Cochrane Central. RESULTS: Of 35 included studies, spin was present in 57%. Within these, 95% had spin present in the abstract and 80% in the conclusion of the article. There was no association between study size and spin (p > 0.05). However, presence of spin in studies positively minded towards robot-assisted hernia repair was higher (p < 0.001) compared with those against or being neutral in their view of the procedure. Furthermore, being funded by or receiving grants from Intuitive Surgical were associated with a higher prevalence of spin (p < 0.05) compared with those who were not. CONCLUSION: Spin was found to be common in articles reporting on robot-assisted groin hernia repair, and presence of spin was higher in studies funded by or receiving grants from the robot company. This suggests that readers should be cautious when reading similar literature.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Hansen DL, Fonnes S, Rosenberg J, et al. Spin is present in the majority of articles evaluating robot-assisted groin hernia repair: a systematic review. Surg Endosc. 2022. PMID: 35024934. doi:10.1007/s00464-021-08990-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。