阻抗平面测量揭示胃食管结合部顺应性在胃底折叠术中的变化

Impedance planimetry (EndoFLIP™) reveals changes in gastroesophageal junction compliance during fundoplication.
PubMed 文献 · Surg Endosc · 2022-01-11

结果显示顺应性与扩张性强相关(r=0.96),折叠后GEJ顺应性80-92 mm3/mmHg与最佳患者报告结局相关,≤79 mm3/mmHg时吞咽困难比例最高。

要点

  • 胃底折叠术中GEJ顺应性在疝复位后为168±74 mm3/mmHg,脚部修补后降至79±39 mm3/mmHg,折叠后为90±33 mm3/mmHg(各比较p<0.05)。
  • 折叠后GEJ顺应性80-92 mm3/mmHg与最佳患者报告结局评分相关。
  • GEJ顺应性≤79 mm3/mmHg与最高吞咽困难报告比例相关。

核心结论

  • 顺应性与扩张性强相关(r=0.96),在抗反流手术中呈现相同方向的变化。
  • GEJ顺应性80-92 mm3/mmHg显示最佳患者报告结局评分,避免顺应性≤79 mm3/mmHg可能预防术后吞咽困难。
  • GEJ顺应性是未充分利用的FLIP测量指标,值得进一步研究。

主要发现

  • 顺应性与扩张性强相关(r=0.96),术中特定时间点测量趋势相似。
  • 疝复位后GEJ顺应性为168±74 mm3/mmHg,脚部修补后为79±39 mm3/mmHg,胃底折叠后为90±33 mm3/mmHg(所有比较p<0.05)。
  • 胃底折叠后GEJ顺应性80-92 mm3/mmHg与最佳患者报告结局评分相关。
  • 顺应性≤79 mm3/mmHg的患者报告吞咽困难的比例最高。

临床怎么用

  • 术中FLIP测量的GEJ顺应性可用于评估抗反流手术效果,折叠后顺应性80-92 mm3/mmHg与最佳患者报告结局相关。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Compliance is the ability of a hollow organ to dilate and increase volume with an increase in pressure, an accurate representation of food bolus transit through the gastroesophageal junction (GEJ). Impedance planimetry system can calculate compliance (change in volume over pressure) and distensibility (cross-sectional area over pressure) of the GEJ. We aim to describe the changes in compliance during anti-reflux surgery and hypothesize that compliance is a better predictor of patient outcomes than distensibility (DI). METHODS AND PROCEDURES: A review of a prospectively maintained quality database was performed. Patients with FLIP measurements during laparoscopic fundoplication between August 2018 and June 2021 were included. GEJ compliance and DI were measured after hernia reduction, cruroplasty, and fundoplication. Patient-reported outcomes were collected through standardized surveys up to 2 years after surgery. A scatter plot was used to identify a correlation between compliance and DI. Comparisons of measurements between time points were made using paired t-tests. Spearman's correlation coefficients (ρ), Wilcoxon rank-sum, and chi-square tests were used to evaluate associations between measurements and outcomes. RESULTS: One hundred and forty-four patients underwent laparoscopic fundoplication. Compliance is strongly associated with DI (r = 0.96), and a comparison of measurements showed similar trends at specific time points during the operation. After hernia reduction, compliance at the GEJ was 168 ± 74 mm3/mmHg, cruroplasty 79 ± 39 mm3/mmHg, and fundoplication 90 ± 33 mm3/mmHg (all comparisons p < 0.05). GEJ compliance of 80-92 mm3/mmHg after fundoplication was associated with the best patient-reported outcome scores. A compliance of ≤ 79 mm3/mmHg had the highest percentage of patients who reported dysphagia. CONCLUSIONS: Compliance and DI are strongly associated displaying the same directional change during anti-reflux surgery. GEJ compliance of 80-92 mm3/mmHg revealed the best patient-reported outcome scores, and avoiding a compliance ≤ 79 mm3/mmHg may prevent postoperative dysphagia. Therefore, GEJ compliance is an underutilized FLIP measurement warranting further investigation.