Titan SGS吻合器纵向胃切除多中心研究
本研究纳入61例患者,使用Titan SGS吻合器行纵向胃切除,记录围手术期干预及术后不良事件,术后第1天行上消化道检查并随访6周。结果显示外科医生对术中器械使用及术后胃囊形态反馈积极,不良事件轻微且为减重手术常见效应,1例术后出血需手术回院但未发现明确出血血管。结论认为Titan SGS吻合器在袖状胃胃囊创建中安全有效。
要点
- 61例患者使用Titan SGS吻合器行纵向胃切除,术后随访6周。
- 不良事件轻微且为减重手术常见效应,1例术后出血需手术回院。
- 外科医生对术中器械使用及术后胃囊形态反馈积极。
核心结论
- Titan SGS吻合器在袖状胃胃囊创建中安全有效。
研究设计与样本
- 多中心研究,纳入61例患者行纵向胃切除,记录围手术期干预及术后不良事件,术后第1天上消化道检查,随访6周。
主要发现
- 外科医生对术中器械使用及术后胃囊形态反馈积极。
- 不良事件轻微、有限且为减重手术常见效应。
- 1例术后出血需手术回院,未发现明确出血血管。
临床怎么用
- 原文未给出具体临床操作推荐。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Standardization of the laparoscopic sleeve gastrectomy procedure is needed to improve patient outcomes. A single-fire 23 cm stapler was developed to streamline the operation. Comparative testing conducted on excised human tissue has demonstrated the superiority of the novel Titan SGS stapler to two commonly utilized commercial devices in both staple line integrity and burst pressure. We hypothesized that the stapler would be safe and effective in creating longitudinal gastric resections in human patients. METHODS: 61 patients were enrolled to undergo gastric resection with the Titan SGS stapler. Perioperative interventions and post-operative adverse events were recorded. Upper GI study was completed on post-operative day 1, and patients were followed for 6 weeks post-operatively to determine any subacute device-related adverse events. RESULTS: Surgeon feedback for intraoperative device utilization and post-operative gastric pouch shape were positive. Adverse events were found to be mild, limited, and generally well-known effects of bariatric surgery. One episode of post-operative hemorrhage required surgical takeback, with no criminal bleeding vessel identified. CONCLUSION: The Titan SGS stapler is both safe and effective in sleeve gastrectomy pouch creation.
引用
- Salyer CE, Thompson J, Hoffman A, et al. Multisite study of Titan SGS stapler in longitudinal gastric resection. Surg Endosc. 2022. PMID: 35080675. doi:10.1007/s00464-022-09051-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。