文献速递胃肠外科围术期管理与 ERAS

腹腔镜袖状胃切除术中较短钉仓的中性效应

Surprising neutral effect of shorter staple cartridges in laparoscopic sleeve gastrectomy.
PubMed 文献 · Surg Endosc · 2021-11-12

本研究回顾性分析单中心2014年1月1日至2019年12月31日全部腹腔镜袖状胃切除术病例,比较使用白色钉仓(闭合高度较短)与仅使用绿/蓝钉仓两组患者的术后结局。结果显示两组在术后漏、出血、狭窄、再入院或死亡方面无显著差异,较短闭合高度钉仓未影响术后出血或漏发生率。

要点

  • 共识建议腹腔镜袖状胃切除术避免使用闭合高度小于1.5 mm的钉仓,但支持数据少。
  • 共纳入1710例患者,绿/蓝组974例,白色钉仓组736例。
  • 使用白色钉仓与标准蓝绿钉仓组合相比,术后漏、出血、狭窄、再入院或死亡无显著差异。

核心结论

  • 腹腔镜袖状胃切除术中使用闭合高度较短的钉仓未影响术后出血或漏发生率,选择较短钉仓以实现更多组织压迫的影响可能有限。

研究设计与样本

  • 单中心回顾性分析,纳入2014年1月1日至2019年12月31日所有腹腔镜袖状胃切除术病例,共1710例,其中绿/蓝组974例,白色钉仓组736例。

主要发现

  • 白色钉仓组与绿/蓝组相比,术后漏、出血、狭窄、再入院或死亡均无显著差异。

关键数值与推荐

  • 共识建议腹腔镜袖状胃切除术避免使用闭合高度小于1.5 mm的钉仓。
  • 白色钉仓组定义为使用任何白色钉仓的病例,绿/蓝组定义为未使用白色钉仓的病例。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Consensus agreements regarding laparoscopic sleeve gastrectomy (LSG) advise against using staple loads less than 1.5 mm in closed staple height. However, few data exist to support this recommendation. We hypothesized that using staples with a shorter closed height would actually decrease incidence of intraoperative and postoperative bleeding during LSG, while not increasing the incidence of leak. METHODS: All LSG cases for a single institution from 1/1/2014 to 12/31/2019 were exported for analysis. Two cohorts were established: 1. 'Green/Blue' group was cases in which no white cartridges were used and 2. 'White' group was cases in which any white cartridges were used. Demographic variables, procedural characteristics, hospital length of stay, and postoperative outcomes were compared between groups. RESULTS: The study populations included 1710 patients, 974 in the green/blue group and 736 in the white cartridge group. There were no significant differences in postoperative leak, bleed, stricture, readmission, or death while using white staple loads as compared with the standard combination of blue and green loads. CONCLUSION: Using staples with a shorter closed height during LSG did not impact the postoperative bleeding or leak rate. The impact from selection of shorter staples to achieve more tissue compression may be limited.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Salyer CE, Thompson J, Hanseman D, et al. Surprising neutral effect of shorter staple cartridges in laparoscopic sleeve gastrectomy. Surg Endosc. 2021. PMID: 34767062. doi:10.1007/s00464-021-08865-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。