AI增强超分辨率手持超声用于社区筛查颈动脉斑块检测
研究开发Hyper-CycleGAN超分辨率重建模型,在127例患者198个斑块的临床队列中验证,并应用于117名社区筛查参与者153个斑块,以便携超声为参考标准。社区筛查中AI增强手持超声识别94.8%颈动脉斑块,标准手持超声为87.6%,狭窄分级加权κ从0.492升至0.836,超声定义易损斑块敏感性从47.4%升至63.2%,特异度保持较高。
要点
- AI增强手持超声在社区筛查中斑块检出率94.8%,高于标准手持超声的87.6%。
- 狭窄分级与参考标准一致性提高,加权κ从0.492升至0.836。
- 超声定义易损斑块敏感性从47.4%升至63.2%,特异度保持较高。
核心结论
- AI增强手持超声改善社区筛查中颈动脉斑块检测与狭窄评估,支持更准确的风险分层和转诊决策。
研究设计与样本
- 开发Hyper-CycleGAN超分辨率重建模型,在127例患者198个斑块的临床队列中验证。
- 将验证模型应用于117名社区筛查参与者153个斑块,以便携超声为参考标准。
主要发现
- 社区筛查中AI增强手持超声识别94.8%颈动脉斑块,标准手持超声为87.6%。
- 狭窄分级与参考标准一致性改善,加权κ从0.492升至0.836。
- 超声定义易损斑块敏感性从47.4%升至63.2%,特异度保持较高。
关键数值与推荐
- 斑块检出率:AI增强手持超声94.8%,标准手持超声87.6%。
- 狭窄分级加权κ:AI增强手持超声0.836,标准手持超声0.492。
- 易损斑块敏感性:AI增强手持超声63.2%,标准手持超声47.4%。
临床怎么用
- 在社区和基层筛查中,AI增强手持超声可提高颈动脉斑块检出和狭窄评估准确性。
- 该技术有望辅助更准确的风险分层和转诊决策,扩大低成本卒中预防策略的可及性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Ann Fam Med . 2026 Sep 21;24(5):437-446. doi: 10.1370/afm.250838. ABSTRACT PURPOSE: Ischemic stroke is a leading cause of disability and death, and early identification of carotid atherosclerotic plaques is critical for stroke prevention in primary care and community settings. We examined whether artificial intelligence (AI)-enhanced handheld ultrasound (HHUS) could improve carotid plaque detection and stenosis assessment in community-based primary care screening. METHODS: We developed a super-resolution reconstruction model (Hyper-CycleGAN) and validated it in a clinical cohort of 127 patients with 198 plaques. The validated model was then applied in a community screening setting with 117 participants and 153 plaques, using portable ultrasound as the reference standard. We evaluated agreement with the reference standard (Bland-Altman, intraclass correlation coefficient) and community diagnostic performance (detection rates, quadratic-weighted Cohen κ, confusion matrices, and standard metrics). RESULTS: In community screening, AI-enhanced HHUS identified 94.8% of carotid plaques compared with 87.6% using standard HHUS. Agreement in stenosis grading with the reference standard improved, with weighted κ increasing from 0.492 to 0.836. Sensitivity for identifying ultrasound-defined vulnerable plaques increased from 47.4% to 63.2%, and specificity remained high. CONCLUSIONS: AI-enhanced HHUS improved carotid plaque detection and stenosis assessment in community screening, supporting more accurate risk stratification and referral decisions in primary care. This approach could expand access to low-cost stroke prevention strategies in underserved communities.Abstract available in: يبرع (Arabic); (Chinese); Francais (French); Deutsch (German); हिन्दी (Hindi); Indonesian (Indonesian); (Japanese); Portugues (Portuguese); Español (Spanish). PMID: 42767949 | PMC: PMC13592921 | DOI: 10.1370/afm.250838
引用
- PubMed · Ann Fam Med:AI-Enhanced Super-Resolution Handheld Ultrasound for Carotid Plaque Detection in Community Screening
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。