文献速递慢病管理老年与多病共存

视网膜数字摄影在基层糖尿病视网膜病变筛查中的诊断效能

Diagnostic performance of retinal digital photography for diabetic retinopathy screening in primary care.
PubMed 文献 · Fam Pract · 2017-01-01

该研究在基层医疗中纳入219例2型糖尿病患者,使用免散瞳视网膜相机分别在有或无药物散瞳条件下拍摄眼底照片,由3名受训家庭医生阅片并与2名眼科医生(金标准)比较。家庭医生诊断糖尿病视网膜病变的平均敏感度为82.9%(66.7-94.8%),特异度为92%(90.2-93.3%),准确度为90.3%(88.2-93%),阳性预测值为71.2%(68-75.5%)。无药物散瞳时14.8%照片无法判读,使用散瞳滴眼液后降至8.7%(McNemar检验,P<0.005),65岁以上患者散瞳后可读性改善更明显(P=0.011)。

要点

  • 受训家庭医生阅片诊断糖尿病视网膜病变的准确度达90.3%,敏感度82.9%、特异度92%。
  • 无药物散瞳时14.8%眼底照片无法判读,使用散瞳滴眼液后降至8.7%。
  • 65岁以上患者药物散瞳后照片可读性改善更明显(McNemar检验,P=0.011)。

核心结论

  • 受训家庭医生评估视网膜照片诊断糖尿病视网膜病变表现良好。
  • 老年患者散瞳后可提高照片可读性。

研究设计与样本

  • 在基层医疗服务中纳入219例2型糖尿病患者,使用免散瞳视网膜相机分别在有和无药物散瞳条件下拍摄眼底照片。
  • 由3名受训家庭医生阅片,与2名眼科医生(金标准)比较诊断效能。

主要发现

  • 糖尿病视网膜病变和增殖性糖尿病视网膜病变的患病率分别为19.2%和1.5%。
  • 家庭医生诊断糖尿病视网膜病变的平均敏感度为82.9%(66.7-94.8%),特异度为92%(90.2-93.3%),准确度为90.3%(88.2-93%),阳性预测值为71.2%(68-75.5%)。
  • 校正kappa系数在视网膜病变为0.74至0.8,在黄斑水肿为0.88至0.92。
  • 无药物散瞳时14.8%照片无法判读,使用散瞳滴眼液后降至8.7%(McNemar检验,P<0.005)。
  • 65岁以上患者药物散瞳后照片可读性改善更明显(McNemar检验,P=0.011)。

临床怎么用

  • 在基层医疗中,受训家庭医生可借助视网膜数字摄影进行糖尿病视网膜病变筛查。
  • 对老年患者考虑药物散瞳以提高眼底照片可读性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: We must study alternatives to structure an effective diabetic retinopathy screening program for Brazilian public health system. OBJECTIVES: Evaluate the diagnostic performance of retinal digital photography for diabetic retinopathy screening in primary care, accuracy of the family physician in diabetic retinopathy identification compared to the ophthalmologist, and the need for dilation. METHODOLOGY: In a primary care service were performed retinal photographs with non-mydriatic Retinal Camera in 219 type 2 diabetic patients with and without medication mydriasis. We evaluated the performance of the diagnostic of the photos graded by three family physicians with training compared to two ophthalmologists (gold standard), and explore related factors with the need for mydriasis pharmacologically. RESULTS: The prevalence of diabetic retinopathy and proliferative diabetic retinopathy was 19.2% and 1.5%, respectively. The sensitivity of family physicians to evaluate diabetic retinopathy averaged 82.9% (66.7-94.8%); specificity, 92% (90.2-93.3%); the accuracy, 90.3% (88.2-93%) and positive predictive value, 71.2% (68-75.5%). The agreement calculated using the kappa adjusted coefficient was from 0.74 to 0.8 for retinopathy and 0.88 to 0.92 for macular edema. Without drug mydriasis the photos were unreadable by 14.8%, when using mydriatic collyrium this number decreased to 8.7% (McNemar test, P < 0.005). Patients with more than 65 years old has more readability after drug mydriasis (McNemar test, P = 0.011). CONCLUSION: Trained family physician reached a good performance for evaluation of retinography for diabetic retinopathy. There was improvement in readability with pupil dilation in older patients.

来源:Fam Pract,查看原文。版权归原作者所有。

引用

  1. Rosses APO, Ben ÂJ, Souza CF, et al. Diagnostic performance of retinal digital photography for diabetic retinopathy screening in primary care. Fam Pract. 2017. PMID: 28379410. doi:10.1093/fampra/cmx020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。