文献速递预防保健、筛查与疫苗慢病管理

环境温度对粪便免疫化学检测结直肠癌筛查性能的影响

Fecal Immunochemical Test (FIT) for Colon Cancer Screening: Variable Performance with Ambient Temperature.
PubMed 文献 · J Am Board Fam Med · 2016-01-01

该回顾性队列研究纳入Kaiser Permanente北加州50至75岁筛查人群,共完成1,141,162次FIT检测,发现高温月份FIT阳性率和检出结直肠癌的敏感性均低于低温月份,提示环境温度可能影响FIT性能。

要点

  • 调整试剂盒设计、运输方式或避开高温时段可能优化FIT性能。

核心结论

  • 在高环境温度下完成的FIT检测阳性率和检出结直肠癌的敏感性均较低。

研究设计与样本

  • 回顾性队列研究,纳入Kaiser Permanente北加州结直肠癌筛查项目中50至75岁、2007年起每年邮寄FIT kit的筛查合格成员。

主要发现

  • 共472,542名患者完成1,141,162次FIT检测,周阳性率范围为2.6%至8.0%(中位数4.4%)。

临床怎么用

  • 在高温季节或地区开展FIT筛查时,应意识到阳性率和敏感性可能降低,必要时优化试剂盒设计或运输方式。
  • 调整策略时需权衡检测复杂性增加和患者依从性下降的风险,并开展仔细研究。

局限性

  • 原文未报告需补充的局限性内容。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Fecal immunochemical tests (FITs) are widely used in colorectal cancer (CRC) screening, but hemoglobin degradation, due to exposure of the collected sample to high temperatures, could reduce test sensitivity. We examined the relation of ambient temperature exposure with FIT positivity rate and sensitivity. METHODS: This was a retrospective cohort study of patients 50 to 75 years in Kaiser Permanente Northern California's CRC screening program, which began mailing FIT kits annually to screen-eligible members in 2007. Primary outcomes were FIT positivity rate and sensitivity to detect CRC. Predictors were month, season, and daily ambient temperatures of test result dates based on US National Oceanic and Atmospheric Administration data. RESULTS: Patients (n = 472,542) completed 1,141,162 FITs. Weekly test positivity rate ranged from 2.6% to 8.0% (median, 4.4%) and varied significantly by month (June/July vs December/January rate ratio [RR] = 0.79, 95% confidence interval [CI], 0.76 to 0.83) and season. FIT sensitivity was lower in June/July (74.5%; 95% CI, 72.5 to 76.6) than January/December (78.9%; 95% CI, 77.0 to 80.7). CONCLUSIONS: FITs completed during high ambient temperatures had lower positivity rates and lower sensitivity. Changing kit design, specimen transportation practices, or avoiding periods of high ambient temperatures may help optimize FIT performance, but may also increase testing complexity and reduce patient adherence, requiring careful study.

来源:J Am Board Fam Med,查看原文。版权归原作者所有。

引用

  1. Doubeni CA, Jensen CD, Fedewa SA, et al. Fecal Immunochemical Test (FIT) for Colon Cancer Screening: Variable Performance with Ambient Temperature. J Am Board Fam Med. 2016. PMID: 28076249. doi:10.3122/jabfm.2016.06.160060

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。