在基层糖尿病门诊测量步行速度的可行性研究
该研究在英国全科糖尿病门诊连续招募可走动患者,评估计时步行、加速度计和跑台步行三种步行速度测量方法的可行性。结果显示招募率91%(30/33),计时步行最可行且患者与员工接受度最高;计时步行平均速度与加速度计和跑台步行相似,但计时步行与跑台步行的一致性界限较宽。
要点
- 计时28米步行是基层糖尿病门诊最可行、接受度最高的步行速度测量方法。
- 计时步行平均速度与加速度计和跑台步行相似,但计时步行与跑台步行一致性界限较宽。
- 跑台步行耗时较长且可行性最低。
核心结论
- 计时步行在基层糖尿病门诊中最为可行且被患者和员工接受,其平均速度与加速度计和跑台步行相似。
研究设计与样本
- 研究连续招募可走动的全科糖尿病门诊患者,同意者进行计时28米步行(4×7米)、加速度计佩戴和3分钟跑台步行,6个月后重复测量。
- 采用Bland-Altman一致性界限评估不同方法间及不同时间点间的步行速度差异。
主要发现
- 招募率为91%(30/33),参与者平均年龄59.6岁(范围37-75),平均体重指数30.6 kg/m2(21.0-46.4),17%有心血管疾病史。
- 计时步行、加速度计和跑台步行的平均(SD)速度分别为1.12(0.13)、1.15(0.16)和1.01(0.39)m/s。
- Bland-Altman分析显示重复测试间及方法间平均一致性良好,但计时步行与跑台步行的一致性界限较宽。
- 来自7名参与者和3名诊所员工的反馈表明所有测试均可接受,但跑台测试耗时较长且可行性最低。
关键数值与推荐
- 计时28米步行(4×7米)于手术走廊按平常速度进行,同时佩戴加速度计,随后进行3分钟跑台步行。
- 6个月后重复上述测量。
临床怎么用
- 在基层糖尿病门诊中可优先采用计时步行评估步行速度,因其可行性及接受度最高。
局限性
- 原文未报告
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Usual walking speed may predict cardiovascular disease in type 2 diabetes, but it is not routinely assessed in UK primary care. OBJECTIVE: To examine the feasibility of three methods of assessing walking speed in patients with diabetes in general practice: timed walking, accelerometry, and treadmill walking. METHODS: We approached consecutive mobile patients attending a general practice diabetes clinic. Consenting participants performed a timed 28-m walk (4 × 7 m) at their usual pace in the surgery corridor while wearing an accelerometer, followed by a 3-minute treadmill walk. Measures were repeated after 6 months. Differences in walking speeds between methods and between timepoints were assessed by Bland-Altman limits of agreement. RESULTS: Recruitment rate was 91% (30/33). Mean age of participants was 59.6 years (range 37-75), mean body mass index was 30.6 kg/m2 (21.0-46.4), and 17% had a history of cardiovascular disease. Average duration of diabetes was 10 years (range 1-40). Twenty-five participants (83%) repeated assessments at 6-month follow-up.Average (SD) walking speed on the timed walk was similar to both accelerometer and treadmill: 1.12 (0.13), 1.15 (0.16), and 1.01 (0.39) m/s, respectively. Bland-Altman analysis showed good agreement for repeat tests and, on average, between methods. Limits of agreement between timed walk and treadmill were wide. Feedback from seven participants and three practice staff indicated acceptability of all tests, but treadmill testing took longer and least feasible. CONCLUSIONS: Timed walk was the most feasible and acceptable to patients and staff. Results were similar on average to accelerometry and treadmill.
引用
- Baskerville R, Reid F, Dawes J, et al. Feasibility of measuring walking speed in a diabetes clinic in primary care. Fam Pract. 2026. PMID: 42837110. doi:10.1093/fampra/cmag067
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。