文献速递预防保健、筛查与疫苗

患者使用五种粪便免疫化学检测的困难与偏好

Patients' Difficulties with Five Different Fecal Immunochemical Tests.
PubMed 文献 · J Am Board Fam Med · 2024-01-01

研究纳入2148名计划接受结肠镜检查者,比较5种粪便免疫化学检测(FIT)的采集难度与偏好。61%参与者偏好液体小瓶,仅9%偏好卡片;49%使用Hemoccult ICT无困难,液体小瓶无困难比例为66%至70%。感知困难与FIT采集错误及品牌显著相关。

要点

  • 液体小瓶FIT比卡片式更受患者偏好,无困难比例更高。
  • Hemoccult ICT的困难包括脏乱、采集窗口太小、取样困难。
  • FIT采集错误与感知困难显著相关,诊室应确保患者理解采集任务。

核心结论

  • 参与者强烈偏好液体小瓶而非卡片式FIT。
  • 感知困难与FIT采集错误及FIT品牌显著相关。
  • 提供FIT的医疗诊室应确保患者理解采集任务以减少错误。

研究设计与样本

  • 前瞻性邀请计划接受结肠镜检查者参与比较5种FIT检测特性的研究。
  • 共纳入2148名参与者,平均年龄63岁,63%女性,83%白人,19%西班牙裔。
  • 通过产品问卷询问采集便利性和困难。

主要发现

  • 1265名(61%)偏好液体小瓶,181名(9%)偏好卡片。
  • 49%使用Hemoccult ICT无困难,66%至70%使用液体小瓶无困难。
  • Hemoccult ICT困难包括脏乱(21%)、采集窗口太小(19%)、取样到棒上(8%)。
  • 液体小瓶困难包括探测或刮取粪便困难(5%至8%)和说明不清(3%)。
  • 多变量模型中,Hemoccult ICT感知困难显著高于OC-Auto Micro(AOR 4.05),有FIT错误者感知困难显著更高(AOR 3.90)。

临床怎么用

  • 诊室提供FIT时应确保患者理解采集任务以最小化错误。
  • 可优先考虑患者偏好的液体小瓶式FIT。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: At least 26 different fecal immunochemical tests (FITs) are available for use in the US. Liquid vial and card collection devices are available. OBJECTIVES: 1) assess participant's difficulties with and preferences for types of FITs; 2) assess whether errors in FIT collection were associated with FIT collection difficulty; 3) identify factors associated with difficulty with FIT stool collection. METHODS: Prospective individuals scheduled for a colonoscopy were invited to participate in a study comparing test characteristics of 5 FITs. A product questionnaire asked participants about ease of collection and difficulties. RESULTS: 2,148 participants; mean age 63 years; 63% females, 83% Whites, and 19% Hispanics. 1265 (61%) preferred use of a liquid vial versus 181 (9%) the card. 49% had no difficulty with Hemoccult ICT, and 66 to 70% had no difficulty with the liquid vials. Difficulties with Hemoccult ICT included: being messy (21%), collection window too small (19%), and getting sample on stick (8%). Difficulties with the liquid vials included difficulty probing or scraping the stool (5% to 8%) and unclear directions (3%). In a multivariable model, the perceived difficulty in FIT collection was significantly higher for Hemoccult ICT compared with OC-Auto Micro (adjusted odds ratio [AOR], 4.05), and it was significantly high for those with a FIT error (AOR, 3.90). CONCLUSION: Participants strongly preferred a liquid vial compared with a card. Perceived difficulty was significantly associated with FIT errors and with FIT brand. Medical offices providing FITs should ensure that patients understand the task of FIT collection, so that errors are minimized.

来源:J Am Board Fam Med,查看原文。版权归原作者所有。

引用

  1. Daly JM, Xu Y, Levy BT, et al. Patients' Difficulties with Five Different Fecal Immunochemical Tests. J Am Board Fam Med. 2024. PMID: 40118555. doi:10.3122/jabfm.2023.230469R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。