要点

  • 控制项从3个减至2个使平均调整时间减少约50%,对组平均输出影响可忽略。
  • 个体自调输出在高低频的重复性均在±4 dB内,且不受助听器使用经验影响。
  • 自调后整体输出±7 dB变化未显著改变组平均音素识别。

核心结论

  • 对许多听力损失成人,探索-选择法自调放大可得到数dB内可重复的输出,且相对不受调整参数数量与顺序影响。

主要发现

  • 控制项从3个减至2个使平均调整时间减少约50%,但对组平均输出反应影响可忽略。
  • 以高频输出而非整体输出作为初始调整,使组平均自调输出在1 kHz以下降低2至3 dB。
  • 在高频,三分之二参与者自调输出在NAL-NL2处方(65 dB SPL言语输入)±5 dB内;低频略超半数。
  • 6次自调中,个体在高频和低频平均自调至自身均值±4 dB内,助听器使用者与非使用者间无差异证据。
  • 自调后整体输出±7 dB变化未显著影响组平均音素识别。

关键数值与推荐

  • 个体自调输出与NAL-NL2处方(65 dB SPL言语输入)比较:高频三分之二参与者在±5 dB内,低频略超半数。
  • 6次自调重复性:个体在高频和低频平均自调至自身均值±4 dB内。
  • 音素识别评估在安静环境下以单音节词进行,水平为相对于起始和自调条件的-14、-7、0和+7 dB。

临床怎么用

  • 探索-选择法自调放大可用于许多听力损失成人,输出重复性在数dB内,减少控制项可缩短调整时间。
  • 自调后整体输出±7 dB变化未显著影响组平均音素识别,提示平均听者处于音素识别-幅度函数平台区。

局限性

  • 研究在安静环境下单耳呈现,未评估噪声环境或双耳佩戴效果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: This study was a continuation of work on an explore-and-select approach to the self-adjustment of amplification. Goals were to determine (i) the effect of changing the number of adjustment controls from three to two, (ii) the effect of changing the initial adjustment from overall output to high-frequency output, (iii) individual repeatability, (iv) the effect on phoneme recognition of increasing and decreasing overall output relative to the starting and adjusted conditions, and (v) listener reactions to, and opinions of, the self-adjustment procedure. DESIGN: Twenty-two adults with hearing loss, 10 of whom were hearing aid users, adjusted level and spectrum of connected speech to preference, using three configurations of number and order of adjustment parameters. The three adjustments were replicated to give a total of six. Presentation was monaural, in quiet, using the ear with the better threshold at 2 kHz. The starting condition was a generic prescription for a typical mild-to-moderate hearing loss. Real ear output spectra were measured for the 6 self-adjustments, the generic starting condition, and the individual NAL-NL2 prescriptions for speech at 65 dB SPL. Monaural phoneme recognition in monosyllables was assessed, in quiet, at levels of -14, -7, 0 and +7 dB relative to both the starting and the self-adjusted conditions. Participants completed a questionnaire and their comments on each question were transcribed. RESULTS: Changing the number of listener controls from 3 to 2 reduced mean adjustment time by around 50% but had negligible effect on group-mean output response. Starting adjustment with high-frequency output rather than overall output resulted in a 2 to 3 dB reduction of group-mean self-adjusted output below 1 kHz. Individual self-adjustments were within ±5 dB of NAL-NL2 prescription (for a 65 dB SPL speech input) for two-thirds of the participants in the high frequencies and for just over half in the low frequencies. In six self-adjustments, individuals self-adjusted, on average, to within ±4 dB of their own mean in both high and low frequencies. There was no evidence that these findings differed for hearing aid users and nonusers. Changes of overall output by ±7 dB after self-adjustment did not significantly affect group mean phoneme recognition. Preference for number and order of self-adjustment differed among participants, as did opinions on self-fitting of hearing aids. CONCLUSIONS: These findings support the conclusion that, for many adults with hearing loss, an explore-and-select procedure for self-adjustment of amplification leads to output values that are repeatable within a few dB, are relatively immune to the number and order of adjustment parameters, and place the average listener well along the plateau of a phoneme recognition versus amplitude function.