文献速递耳科与耳神经

超薄直电极与超薄蜗轴电极人工耳蜗的言语识别结局比较

Speech Recognition Outcomes in Adults With Slim Straight and Slim Modiolar Cochlear Implant Electrode Arrays.
PubMed 文献 · Otolaryngol Head Neck Surg · 2021-08-17

回顾性队列研究比较CI532超薄蜗轴电极与CI522超薄侧壁电极成人植入者的术后AzBio安静言语识别,匹配术前评分及纯音平均后,两组最终随访得分无显著差异,但术前AzBio<10%者SLW组6个月得分更优。

要点

  • SLW与SME电极在匹配术前言语及纯音平均后,术后安静AzBio得分无显著差异。
  • 术前AzBio<10%者,SLW组6个月AzBio得分显著优于SME组。
  • SME组术中尖端卷曲发生率8%,SLW组为0%。

核心结论

  • SLW和SME人工耳蜗植入均能提供相当的听力学功能改善。
  • 与SLW相比,SME并未表现出更优的言语识别结局。

研究设计与样本

  • 回顾性队列研究,比较成人CI532(SME,n=37)与CI522(SLW,n=52)植入者术后AzBio安静句子得分。
  • 按术前安静AzBio得分及助听/未助听听阈平均进行匹配。

主要发现

  • SLW组与SME组平均年龄分别为62.0(18.2)岁与62.6(14.6)岁。

关键数值与推荐

  • 术中尖端卷曲发生率SME组为8%,SLW组为0%。

临床怎么用

  • 对于术前言语识别极差(AzBio<10%)的成人,可优先考虑SLW电极以争取更优短期言语识别。
  • SME电极植入需注意术中尖端卷曲风险。

局限性

  • 回顾性研究设计。
  • 随访时间较短(约9-10个月)。
  • 样本量有限,非随机分组。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To compare differences in audiologic outcomes between slim modiolar electrode (SME) CI532 and slim lateral wall electrode (SLW) CI522 cochlear implant recipients. STUDY DESIGN: Retrospective cohort study. SETTING: Tertiary academic hospital. METHODS: Comparison of postoperative AzBio sentence scores in quiet (percentage correct) in adult cochlear implant recipients with SME or SLW matched for preoperative AzBio sentence scores in quiet and aided and unaided pure tone average. RESULTS: Patients with SLW (n = 52) and patients with SME (n = 37) had a similar mean (SD) age (62.0 [18.2] vs 62.6 [14.6] years, respectively), mean preoperative aided pure tone average (55.9 [20.4] vs 58.1 [16.4] dB; P = .59), and mean AzBio score (percentage correct, 11.1% [13.3%] vs 8.0% [11.5%]; P = .25). At last follow-up (SLW vs SME, 9.0 [2.9] vs 9.9 [2.6] months), postoperative mean AzBio scores in quiet were not significantly different (percentage correct, 70.8% [21.3%] vs 65.6% [24.5%]; P = .29), and data log usage was similar (12.9 [4.0] vs 11.3 [4.1] hours; P = .07). In patients with preoperative AzBio <10% correct, the 6-month mean AzBio scores were significantly better with SLW than SME (percentage correct, 70.6% [22.9%] vs 53.9% [30.3%]; P = .02). The intraoperative tip rollover rate was 8% for SME and 0% for SLW. CONCLUSIONS: Cochlear implantation with SLW and SME provides comparable improvement in audiologic functioning. SME does not exhibit superior speech recognition outcomes when compared with SLW.

来源:Otolaryngol Head Neck Surg,查看原文。版权归原作者所有。

引用

  1. MacPhail ME, Connell NT, Totten DJ, et al. Speech Recognition Outcomes in Adults With Slim Straight and Slim Modiolar Cochlear Implant Electrode Arrays. Otolaryngol Head Neck Surg. 2021. PMID: 34399646. doi:10.1177/01945998211036339

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。