EasyMDT:测量时间调制检测的简易工具评估
本文介绍并评估了EasyMDT软件工具,用于测量宽带噪声载波的时间调制检测阈值。研究在正常听力者和人工耳蜗(CI)使用者中测量调制检测阈值,并与言语识别及频谱-时间分辨率指标比较。结果显示EasyMDT阈值与既往报道一致,单一调制频率阈值可预测全曲线阈值,且100 Hz阈值与多项言语任务相关。
要点
- EasyMDT提供标准化刺激和协议,便于临床快速测试时间调制检测。
- 单一频率(100或150 Hz)阈值可预测7频率全曲线阈值。
- CI使用者测试时长从全曲线平均超18分钟降至单频率不足3分钟。
核心结论
- EasyMDT是一款易用、快速的非语言测量工具,可预测言语理解,适合临床或实验使用。
研究设计与样本
- 方法学研究,使用三间隔强制选择自适应任务测量正常听力者和CI使用者的调制检测阈值。
主要发现
- EasyMDT测得的调制检测阈值与既往其他实验室报道一致。
- 单一调制频率(100 Hz或150 Hz)阈值可预测7个调制频率全曲线的阈值。
- CI使用者测试时长从全曲线平均超过18分钟降至单频率测量不足3分钟。
- 100 Hz调制检测阈值与CNC词、辅音识别和噪声中AzBio句子相关,但与元音识别不相关。
- 调制检测与频谱-时间分辨率任务(SMRT)之间未发现相关性。
关键数值与推荐
- 全曲线在单区块内测量7个调制频率(10、50、75、100、150、200、300 Hz)的阈值。
- 单频率区块仅测量100 Hz或150 Hz的调制检测阈值。
- 言语识别任务包括CNC词、辅音识别、元音识别和噪声中AzBio句子;频谱-时间分辨率任务为SMRT。
临床怎么用
- EasyMDT可快速测量时间调制检测阈值,适用于临床环境或实验电池。
- 软件免费下载,提供标准化协议,便于不同研究间直接比较阈值。
局限性
- 仅CI使用者参与言语和频谱-时间测试,正常听力者未参与这些任务。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: A software tool (EasyMDT) that measures temporal modulation detection thresholds of a broadband noise carrier is presented. EasyMDT is designed to be both easy and quick to promote the use in environments where testing time is limited, and testers may not have extensive technical expertise to use typical research software. In addition, by providing a standardized stimulus and protocol, data collected by all groups using the software can be compared directly. Details of EasyMDT, including a description of the protocol, stimuli, interface and how to obtain the software, are provided along with representative sample data from both normal-hearing listeners and cochlear implant (CI) users. Performance with the EasyMDT is compared with speech understanding metrics as well as a metric of spectral-temporal resolution. DESIGN: A "Full Curve" of modulation detection thresholds is measured using a three-interval forced-choice adaptive task in a single block for 7 modulation frequencies (10, 50, 75, 100, 150, 200, and 300 Hz). Similarly, the modulation detection thresholds were measured for only one modulation frequency in a block (either 100 Hz or 150 Hz). Modulation detection thresholds and block duration were recorded. In addition, performance on speech recognition tasks (CNC words, consonant identification, vowel identification, and AzBio sentences in noise) and a spectral-temporal resolution task (SMRT; Aronoff and Landsberger) were measured. Modulation detection thresholds were measured for both normal-hearing listeners and CI users. Only CI users participated in the speech and spectral-temporal tests. RESULTS: Modulation detection thresholds measured with EasyMDT were consistent with those previously reported from other laboratories. Modulation detection thresholds at a single modulation frequency (100 Hz or 150 Hz) were predictive of modulation detection thresholds measured as part of the Full Curve consisting of all 7 modulation frequencies. Testing durations for CI users dropped from an average of over 18 minutes for the Full Curve to under 3 minutes for either of the single modulation frequency measures. Modulation detection thresholds at 100 Hz correlated with CNC words, consonant identification, and AzBio sentences in noise, but not vowel identification. No correlations were found between modulation detection and spectral-temporal resolution. CONCLUSIONS: The EasyMDT is designed to be an easy-to-use tool that provides a nonlinguistic measure that can predict speech understanding. The test duration is short enough that it can be incorporated into clinical practice or as part of an experimental battery. The software is available for free download at https://www.ear-lab.org/software-downloads.html. The software is designed to have a minimum barrier of entry as well as provide a standardized protocol allowing direct comparison of modulation detection thresholds across studies and groups.
引用
- Landsberger DM, Stupak N. Evaluation of a Tool for Measuring Temporal Modulation Detection. Ear Hear. 2022. PMID: 34380982. doi:10.1097/AUD.0000000000001107
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。