单侧聋人工耳蜗双耳时间包络灵敏度定制频率分配图对言语感知和空间听觉无获益
本研究纳入9例单侧聋伴人工耳蜗使用者,基于双耳时间包络差异灵敏度或估计插入深度制作个体化实验性频率分配图(FAT),比较其与临床FAT在空间定位和噪声下言语感知中的效果。结果显示实验FAT与临床FAT平均相差0.15倍频程,但6个月后各指标与临床FAT相比均无显著差异,频率分配偏移大小与感知变化也无明确关系。
要点
- 基于双耳时间包络灵敏度优化FAT未改善单侧聋人工耳蜗使用者的定位或言语感知。
- 实验FAT与临床FAT平均相差0.15倍频程,个体间存在差异。
- 临床频率-位置对齐可能已足够,因人工耳蜗固有频谱分辨率较差。
核心结论
- 将FAT调整至优化双耳时间包络差异灵敏度,并未改善单侧聋伴人工耳蜗使用者的空间定位或言语感知。
研究设计与样本
- 研究纳入9例单侧聋伴人工耳蜗使用者,均有至少6个月人工耳蜗聆听经验。
- 基于双耳时间包络差异灵敏度或估计插入深度制作个体化实验性FAT,并在临床FAT、实验FAT急性及2个月间隔至6个月时测试空间定位和空间共置或分离噪声下的言语感知。
- 随后恢复临床FAT并在急性及1个月后复测以控制长期学习效应。
主要发现
- 实验FAT因聆听者而异,与临床FAT平均相差0.15倍频程。
- 实验FAT使用6个月后与临床FAT恢复1个月后相比,所有测量指标均无显著差异。
- 频率分配偏移大小与感知变化之间无明确关系。
临床怎么用
- 基于双耳时间包络灵敏度定制FAT的临床转化价值有限,临床频率-位置对齐可能已足够。
- 未来研究需考虑双耳时间错位等其他因素,再评估频谱对齐的潜在获益。
局限性
- 样本量较小(9例),可能限制统计效能和结果外推。
- 实验FAT与临床FAT平均差异仅0.15倍频程,调整幅度有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: This study tested whether speech perception and spatial acuity improved in people with single-sided deafness and a cochlear implant (SSD+CI) when the frequency allocation table (FAT) of the CI was adjusted to optimize frequency-dependent sensitivity to binaural disparities. DESIGN: Nine SSD+CI listeners with at least 6 months of CI listening experience participated. Individual experimental FATs were created to best match the frequency-to-place mapping across ears using either sensitivity to binaural temporal-envelope disparities or estimated insertion depth. Spatial localization ability was measured, along with speech perception in spatially collocated or separated noise, first with the clinical FATs and then with the experimental FATs acutely and at 2-month intervals for 6 months. Listeners then returned to the clinical FATs and were retested acutely and after 1 month to control for long-term learning effects. RESULTS: The experimental FAT varied between listeners, differing by an average of 0.15 octaves from the clinical FAT. No significant differences in performance were observed in any of the measures between the experimental FAT after 6 months and the clinical FAT one month later, and no clear relationship was found between the size of the frequency-allocation shift and perceptual changes. CONCLUSION: Adjusting the FAT to optimize sensitivity to interaural temporal-envelope disparities did not improve localization or speech perception. The clinical frequency-to-place alignment may already be sufficient, given the inherently poor spectral resolution of CIs. Alternatively, other factors, such as temporal misalignment between the two ears, may need to be addressed before any benefits of spectral alignment can be observed.
引用
- Dirks CE, Nelson PB, Oxenham AJ, et al. No Benefit of Deriving Cochlear-Implant Maps From Binaural Temporal-Envelope Sensitivity for Speech Perception or Spatial Hearing Under Single-Sided Deafness. Ear Hear. 2022. PMID: 34291758. doi:10.1097/AUD.0000000000001094
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。