单侧聋人工耳蜗在多声源环境下的声源定位行为
结果显示CI开时定位准确度提高,且CI减小了方位旋转和平移维度的头部运动幅度,包括目标声出现前的预期阶段。
要点
- 单侧聋CI使用者在复杂多声源环境中定位准确度提高。
- CI减小了任务中的头部运动幅度,包括目标声出现前的预期阶段。
- 对侧耳高频听力损失降低定位准确度,但不影响CI获益幅度。
核心结论
- 单侧聋CI使用者在包含环境声和行为要素的复杂听声场景中表现出定位获益。
- CI减小了用于完成任务的头部总体运动幅度,且在目标声加入混合声之前即已出现。
- CI可减少预期即将到来的声事件和主动定位目标声时的身体运动需求。
研究设计与样本
- 10例使用者在CI激活前也接受测试以考察纵向效应。
- 在单耳(CI关)和双耳(CI开)配置下完成声源定位任务,并追踪头部运动。
- 2秒环境声样本循环形成4秒或10秒试次,经26只扬声器组成的球阵呈现,覆盖±144°方位角和±30°仰角,半径1米。
- 目标声单独呈现(定位任务)或与1个或3个额外声源同时呈现,目标声通过加入(Add)或移除(Rem)混合声后6秒提示。
主要发现
- CI开时定位准确度提高,但与测试条件无交互作用,且CI对声音识别表现无影响。
- 未植入耳的高频听力损失降低定位准确度和声音识别表现,但CI定位获益幅度与听力损失无关。
- CI减小了方位旋转和平移维度的头部总体运动幅度,在目标声存在时(所有条件)和目标声开启前的预期阶段(Add条件)均如此。
- CI激活前后CI关时的表现无变化。
临床怎么用
- 对于单侧聋使用者,CI可在复杂声环境中改善定位并减少身体运动需求。
- 评估CI获益时应考虑复杂多声源场景和头部运动行为,而非仅用简单声源。
局限性
- 仅10例完成CI激活前测试。
- 研究采用特定实验室声场设置,外推至日常环境需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: For listeners with one deaf ear and the other ear with normal/near-normal hearing (single-sided deafness [SSD]) or moderate hearing loss (asymmetric hearing loss), cochlear implants (CIs) can improve speech understanding in noise and sound-source localization. Previous SSD-CI localization studies have used a single source with artificial sounds such as clicks or random noise. While this approach provides insights regarding the auditory cues that facilitate localization, it does not capture the complex nature of localization behavior in real-world environments. This study examined SSD-CI sound localization in a complex scenario where a target sound was added to or removed from a mixture of other environmental sounds, while tracking head movements to assess behavioral strategy. DESIGN: Eleven CI users with normal hearing or moderate hearing loss in the contralateral ear completed a sound-localization task in monaural (CI-OFF) and bilateral (CI-ON) configurations. Ten of the listeners were also tested before CI activation to examine longitudinal effects. Two-second environmental sound samples, looped to create 4- or 10-sec trials, were presented in a spherical array of 26 loudspeakers encompassing ±144° azimuth and ±30° elevation at a 1-m radius. The target sound was presented alone (localize task) or concurrently with one or three additional sources presented to different loudspeakers, with the target cued by being added to (Add) or removed from (Rem) the mixture after 6 sec. A head-mounted tracker recorded movements in six dimensions (three for location, three for orientation). Mixed-model regression was used to examine target sound-identification accuracy, localization accuracy, and head movement. Angular and translational head movements were analyzed both before and after the target was switched on or off. RESULTS: Listeners showed improved localization accuracy in the CI-ON configuration, but there was no interaction with test condition and no effect of the CI on sound-identification performance. Although high-frequency hearing loss in the unimplanted ear reduced localization accuracy and sound-identification performance, the magnitude of the CI localization benefit was independent of hearing loss. The CI reduced the magnitude of gross head movements used during the task in the azimuthal rotation and translational dimensions, both while the target sound was present (in all conditions) and during the anticipatory period before the target was switched on (in the Add condition). There was no change in pre- versus post-activation CI-OFF performance. CONCLUSIONS: These results extend previous findings, demonstrating a CI localization benefit in a complex listening scenario that includes environmental and behavioral elements encountered in everyday listening conditions. The CI also reduced the magnitude of gross head movements used to perform the task. This was the case even before the target sound was added to the mixture. This suggests that a CI can reduce the need for physical movement both in anticipation of an upcoming sound event and while actively localizing the target sound. Overall, these results show that for SSD listeners, a CI can improve localization in a complex sound environment and reduce the amount of physical movement used.
引用
- Bernstein JGW, Phatak SA, Schuchman GI, et al. Single-Sided Deafness Cochlear Implant Sound-Localization Behavior With Multiple Concurrent Sources. Ear Hear. 2022. PMID: 34320529. doi:10.1097/AUD.0000000000001089
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。