MRI对区域复发灵敏度更高。结论推荐PET/CT作为一线监测影像,MRI用于确认原发部位阳性发现。

要点

  • PET/CT灵敏度更高(0.63 vs 0.40)但特异度较低(0.90 vs 1.0)。
  • MRI对区域复发灵敏度更高(1.0 vs 0.78),推荐PET/CT一线、MRI确认。

核心结论

  • 微血管重建术后原发部位复发监测中,PET/CT灵敏度优于MRI。
  • 推荐PET/CT作为一线影像,MRI用于确认原发部位阳性发现。

研究设计与样本

  • 患者年龄61.4±15.8岁,均接受PET/CT和MRI检查,由两名放射科医生盲法判读。
  • 复发可能性采用连续(0-100)和Likert量表评估,23例(50%)经病理确认复发。

主要发现

  • PET/CT判读「可能」原发复发灵敏度0.63、特异度0.90;MRI灵敏度0.40、特异度1.0。
  • MRI检测区域复发的灵敏度高于PET/CT(1.0 vs 0.78)。

关键数值与推荐

  • PET/CT灵敏度0.63、特异度0.90;MRI灵敏度0.40、特异度1.0。
  • 区域复发检测灵敏度:MRI 1.0 vs PET/CT 0.78。

临床怎么用

  • 微血管重建术后解剖扭曲影响临床评估时,首选PET/CT监测原发部位复发。
  • 原发部位PET/CT阳性时,用MRI确认以降低假阳性。
  • 区域复发监测可考虑MRI因其灵敏度更高。

局限性

  • 仅纳入同时接受PET/CT和MRI的患者,可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES/HYPOTHESIS: To assess the accuracy and utility of positron emission tomography/computed tomography (PET/CT) compared with magnetic resonance imaging (MRI) for detecting head and neck cancer (HNC) recurrence after microvascular reconstructive surgery. STUDY DESIGN: Retrospective cohort study. METHODS: Analysis of HNC patients who underwent microvascular reconstruction at a single, tertiary academic center following ablative surgery from 1998 to 2015. Forty-six patients aged 61.4 ± 15.8 years with both PET/CT and MRI examinations were identified. Two radiologists were blinded and interpreted each imaging study. Recurrence certainty scores were determined via continuous (0-100) and Likert ("Likely" to "Unlikely") scales, with larger values indicating a higher likelihood of recurrence. Pathologic confirmation of recurrence was confirmed in 23 patients (50%). RESULTS: Among those with primary site recurrences, mean recurrence certainty was significantly higher with PET/CT versus MRI on the continuous scale (63.9 vs. 44.4, P = .006). A receiver operating characteristic analysis for predicting primary site recurrence demonstrated a significantly larger area under the curve of 0.79 for PET/CT compared to 0.64 for MRI (P = .044). Categorization of "Likely" primary site recurrence on PET/CT, versus MRI, had higher sensitivity (0.63 vs. 0.40), but lower specificity (0.90 vs. 1.0). MRI demonstrated higher sensitivity (1.0 vs. 0.78) at detecting regional site recurrences. CONCLUSION: PET/CT demonstrates greater sensitivity than MRI as a surveillance tool for primary site recurrence following microvascular reconstruction where clinical evaluation is hindered by anatomical distortion. Therefore, PET/CT should be pursued as first-line imaging, with MRI utilized for confirmation of positive imaging findings at the primary site. LEVEL OF EVIDENCE: 2 Laryngoscope, 131:2713-2718, 2021.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. House AE, Zebolsky AL, Jacobs J, et al. Surveillance Imaging Following Head and Neck Cancer Treatment and Microvascular Reconstruction. Laryngoscope. 2021. PMID: 34156723. doi:10.1002/lary.29700

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。