宽频声能吸收率提升儿童分泌性中耳炎鉴别诊断
本研究纳入49只手术确诊分泌性中耳炎患儿耳和14只无近期中耳炎病史儿童耳,术前测量宽频声能吸收率并按术中积液量分组。结果显示吸收率随积液量增加而系统性降低,以1–5 kHz最明显;多变量逻辑回归区分有无积液及部分/完全积液的曲线下面积为1至0.944,而标准鼓室压图未见积液量的系统性影响。
要点
- 宽频声能吸收率随中耳积液量增加而系统性降低,1–5 kHz最明显。
- 逻辑回归区分有无积液及部分/完全积液的AUC为1至0.944。
- 标准鼓室压图未显示积液量的系统性影响。
核心结论
- 宽频声能吸收率是儿童分泌性中耳炎积液量的强敏感指标。
研究设计与样本
- 比较49只手术确诊分泌性中耳炎患儿耳与14只无近期中耳炎病史儿童耳的宽频声能吸收率。
主要发现
- 吸收率随中耳积液量增加而系统性降低,多数频率存在该现象,1–5 kHz最明显。
- 逻辑回归区分积液存在(完全与部分)与不存在(清晰耳与正常对照)的准确率为100%。
- 逻辑回归区分部分与完全积液的准确率为100%。
- 逻辑回归区分正常对照耳与手术时无积液耳的准确率为75%。
- 按70%训练集与30%验证集划分时,区分有无积液及部分/完全积液的AUC为1至0.944。
临床怎么用
- 可考虑用宽频声能吸收率辅助判断儿童中耳积液是否存在及其为部分或完全。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The objective of this work is to determine whether there is a systematic effect of middle ear effusion volume on wideband acoustic immittance in children with surgically confirmed otitis media with effusion. DESIGN: Wideband acoustic immittance was measured in 49 ears from children (9 months to 11 years) who had a diagnosis of otitis media with effusion and compared to 14 ears from children (10 months to 10 years) without a recent history of otitis media. For children with otitis media with effusion, wideband acoustic immittance testing took place in the child's preoperative waiting room before surgical placement of tympanostomy tubes. Testing was completed in a pressurized condition (wideband tympanometry) for all ears as well as in an ambient condition in a subset of ears. Intraoperative findings regarding effusion volume were reported by the surgeons immediately before tube placement and confirmed following myringotomy. This classified the volume of effusion as compared to middle ear volume categorically as either full, partial, or clear of effusion. The type of wideband acoustic immittance explored in this work was absorbance. Absorbance responses were grouped based on effusion volume into one of four groups: full effusions, partial effusions, ears clear of effusion at the time of surgery, and normal control ears. Standard tympanometry was also completed on all ears. RESULTS: Absorbance is systematically reduced as the volume of the middle ear effusion increases. This reduction is present at most frequencies but is greatest in the frequency range from 1 to 5 kHz. A multivariate logistic regression approach was utilized to classify ears based on effusion volume. The regression approach classified ears as effusion present (full and partial ears) or absent (clear ears and normal control ears) with 100% accuracy, ears with effusion present as either partial or full with 100% accuracy, and ears without effusion as either normal control ears or ears clear of effusion with 75% accuracy. Regression performance was also explored when the dataset was split into a training set (70% of the data) and a validation test set (30% of the data) to simulate how this approach would perform on unseen data in a clinical setting. Accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve are reported. Overall, this approach demonstrates high sensitivity and specificity for classifying ears as effusion being present or absent and as present effusions being full or partial with areas under the curve ranging from 1 to 0.944. Despite the lack of effusion present in both clear ears and normal control ears, this approach was able to distinguish between these ears, but with a more moderate sensitivity and specificity. No systematic effect of effusion volume was found on standard tympanometry. CONCLUSIONS: Wideband acoustic immittance, and more specifically, absorbance, is a strong and sensitive indicator of the volume of a middle ear effusion in children with otitis media with effusion.
引用
- Merchant GR, Al-Salim S, Tempero RM, et al. Improving the Differential Diagnosis of Otitis Media With Effusion Using Wideband Acoustic Immittance. Ear Hear. 2021. PMID: 33928915. doi:10.1097/AUD.0000000000001037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。