文献速递耳科与耳神经

提高数字噪声测试对高频听力损失的敏感性

Improved Sensitivity of Digits-in-Noise Test to High-Frequency Hearing Loss.
PubMed 文献 · Ear Hear · 2021-01-01

本研究通过比较不同低通滤波噪声下数字噪声测试(DIN)的言语接收阈值与纯音平均听阈的相关性,发现4 kHz低通滤波噪声下DIN对高频听力损失(平均PTA_HF≥20 dB)的敏感性最高(92%),特异性为90%。结果表明低通滤波噪声可替代宽带噪声以提高DIN对高频听力损失的早期检测能力。

要点

  • 4 kHz低通滤波噪声下DIN对高频听力损失的敏感性最高(92%)。
  • DIN-SRT与高频PTA(4,8,10,12.5 kHz)在4和8 kHz滤波噪声下相关性最佳。
  • 低通滤波噪声可替代宽带噪声用于DIN以提高高频听力损失的早期检出。

核心结论

  • 在所用滤波器中,4 kHz低通滤波噪声下DIN对高频听力损失的敏感性最高。
  • 低通滤波噪声可有益地替代宽带噪声,以改善DIN对高频听力损失的早期检测。

研究设计与样本

  • 研究纳入60名正常听力者和40名双侧对称感音神经性轻度听力损失者,比较不同噪声掩蔽下的DIN-SRT与纯音平均听阈。
  • 噪声掩蔽包括宽带及截止频率为2、4、8 kHz的低通滤波言语形状噪声。
  • 美国英语数字0至9经等可听度处理后双耳呈现。

主要发现

  • 较窄的掩蔽噪声带宽通常产生更好(更敏感)的平均DIN-SRT。
  • 听力损失组中SRT与PTA呈强且显著的相关。
  • 较低频率PTA(0.5、1、2、4 kHz)与2 kHz滤波噪声下的SRT相关性最高且斜率最陡。
  • 较高频率PTA(4、8、10、12.5 kHz)与4和8 kHz滤波噪声下的SRT相关性最佳。

关键数值与推荐

  • 4 kHz低通滤波器对检测平均PTA_HF≥20 dB的敏感性最高(92%),特异性与8 kHz滤波器并列最高(90%)。

临床怎么用

  • 临床可采用4 kHz低通滤波噪声替代宽带噪声进行DIN测试,以提高对高频听力损失的早期检出。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Hearing loss is most commonly observed at high frequencies. High-frequency hearing loss (HFHL) precedes and predicts hearing loss at lower frequencies. It was previously shown that an automated, self-administered digits-in-noise (DIN) test can be sensitized for detection of HFHL by low-pass filtering the speech-shaped masking noise at 1.5 kHz. This study was designed to investigate whether sensitivity of the DIN to HFHL can be enhanced further using low-pass noise filters with higher cutoff frequencies. DESIGN: The US-English digits 0 to 9, homogenized for audibility, were binaurally presented in different noise maskers including one broadband and three low-pass (cutoff at 2, 4, and 8 kHz) filtered speech-shaped noises. DIN-speech reception thresholds (SRTs) were obtained from 60 normal hearing (NH), and 40 mildly hearing impaired listeners with bilateral symmetric sensorineural hearing loss. Standard and extended high-frequency audiometric pure-tone averages (PTAs) were compared with the DIN-SRTs. RESULTS: Narrower masking noise bandwidth generally produced better (more sensitive) mean DIN-SRTs. There were strong and significant correlations between SRT and PTA in the hearing impaired group. Lower frequency PTALF 0.5,1, 2, 4 kHz had the highest correlation and the steepest slope with SRTs obtained from the 2-kHz filter. Higher frequency PTAHF 4,8,10,12.5 kHz correlated best with SRTs obtained from 4- and 8-kHz filtered noise. The 4-kHz low-pass filter also had the highest sensitivity (92%) and equally highest (with the 8-kHz filter) specificity (90%) for detecting an average PTAHF of 20 dB or more. CONCLUSIONS: Of the filters used, DIN sensitivity to higher frequency hearing loss was greatest using the 4-kHz low-pass filter. These results suggest that low-pass filtered noise may be usefully substituted for broadband noise to improve earlier detection of HFHL using DIN.